Similar Projects
Rooftop Unit
Post-Bid
Anderson, SC 29624

HVAC Replacement at Pelzer Auditorium
Post-Bid
Pelzer, SC 29669

Water Treatment Services
Term Contract
Results
Easley, SC

Provide Two Rooftop Air Handling Units for the Tri-County Technical College Pendleton Campus
Results
Pendleton, SC

HVAC Annual and Periodic Maintenance Services
Post-Bid
Pendleton, SC 29670

Replace AHU-1 - Rich Laboratory
Results
$175,000 to $200,000 est. value
SC

HVAC and Mechanical Products
Term Contract
Post-Bid

AMRL Cooling Tower Upgrade
Results
$425,000 to $450,000 est. value
Anderson, SC 29625

Provide One Rooftop Air Handling Unit
Results
$38,070 est. value
Pendleton, SC

HVAC Equipment Renovations at Riverside Middle School
Results
$1,640,405 est. value
Pendleton, SC 29670

Townville Elementary School HVAC Equipment Replacement
Results
$993,570 est. value
Townville, SC 29689

LaFrance Elementary HVAC Equipment Replacement
Results
Pendleton, SC 29670

Pendleton Elementary HVAC Equipment Replacement
Results
Pendleton, SC 29670

Belton Honea Path High School Roof Top Unit Replacement
Results
Honea Path, SC 29654

HVAC Maintenance
Results
Aiken, Anderson, Barnwell, Beaufort, Bennettsville, Chester, Columbia, Conway, Florence, Greenville, Kingstree, Lancaster, Marion, Orangeburg, Pee Dee, Sumter, SC

Reported 02/04/2020 12:00 AM
Project Title

Chiller Replacement - Nevitt Forest Elementary School

Physical Address View project details and contacts
City, State (County) Anderson, SC 29624   (Anderson County)
Category(s) Single Trades
Sub-Category(s) HVAC
Contracting Method Competitive Bids.
Project Status Bidding
Bids Due View project details and contacts
Estimated Value
Plans Available from County Agency
Owner View project details and contacts
Architect View project details and contacts
Description

Specifications: Remove and dispose of existing water cooled 100 ton chiller and cooling tower Provide and install new Trane CGAM-100 air cooled chiller in area that the cooling tower is presently in Chiller to have factory mounted circuit breaker, architectural louver, sound package, 5 year all parts and 1 year labor warranty Replace chilled water pump with new Taco pump Install new chilled water piping from existing boiler room to new chiller Must include the following: Underground work and coring Heat tape and pipe insulation All electrical and connection to existing controls Enlarging or reconfiguring of equipment pad Exposed outdoor piping to have metal jacket All utility locating to be the responsibility of the successful contractor Any damages to existing utilities to be repaired by successful contractor Price includes all material, labor and equipment rental.

Details

Division 23 - Heating, Ventilating, and Air Conditioning (HVAC), Instrumentation and Control for HVAC, HVAC Air Distribution, Central HVAC Equipment.

Bidder's List View project details and contacts
Prospective Bidders View project details and contacts
Project Documents
 Engineered Spec Sheet
 Architectural Plans
 Other Documents