Similar Projects
Fort Hood Fuel Facility Replacement
Design
$25,000,000 to $100,000,000 est. value
Fort Hood, TX 76544

The Refurbishment of Ground Storage Tank 2 and Hydropneumatic Tank 2 and Generator Fuel Tank Expansion of Water Plant No. 1
Infrastructure
Bidding
TX

Gas Distribution System
Infrastructure
Bidding
Port Aransas, TX

DISD Career Institute North Atmos Gas Main Extension
Infrastructure
Sub-Bidding
Dallas, TX

500,000 Gallon Elevated Storage Tank No. 3 Rehabilitation Project
Post-Bid
Less than $600,000 est. value
Port Neches, TX

Construction of Natural Gas Regulator Station to Serve Beacon Hill Subdivision
Post-Bid
Waller, TX 77484

Fuel Storage Tank Regulatory Testing, Inspection, Preventative Maintenance and Repairs
Results
Frisco, TX 75034

2020 New Gas Gate Station
Results
$170,000 est. value
Sealy, TX 77474

Station Port Aransas - Fuel Farm Reconfiguration
Post-Bid
Port Aransas, TX 78373

Gas Line Construction
Results
Corsicana, TX 75110

Install Water Draw-Off System
Post-Bid
Corpus Christi, TX

Natural Gas Pipeline Removal Project Phase 1
Results
Bryan, TX 77803

Fuel Storage Tank Replacement
Post-Bid
Less than $250,000 est. value
Pearland, TX 77581

Annual Contract for Fuel Site Repairs and Service
Term Contract
Results
Fort Worth, TX 76196

Fleet Facility Fuel
Term Contract
Post-Bid
Galveston, TX 77554

Reported 11/20/2021 12:00 AM
Project Title

Foundation Repair - Chemical Tanks

Physical Address View project details and contacts
City, State (County) Houston, TX 77032   (Harris County)
Category(s) Sewer and Water
Sub-Category(s) Fuel/Chemical Tanks and Lines
Contracting Method Competitive Bids.
Project Status Bidding
Bids Due View project details and contacts
Estimated Value
Plans Available from Municipal Agency
Owner View project details and contacts
Architect View project details and contacts
Description

Repair of (2) chemical tank concrete foundations located at the Intercontinental Treatment Plant Facility. The vendor will have to remove the tanks from the concrete and repair the foundations. The concrete foundation is designed to support vertical, single wall chemical, ICT Model HDXLPE tanks approximately 119 inches in diameter and 163 inches high, capacity 6510 Gallons. Once the vendor repairs the concrete, they will have to install the tanks on the concrete foundations.

Details

Division 02 - Existing Conditions, Subsurface Investigation.
Division 03 - Concrete, Concrete Reinforcing, Cast-in-Place Concrete.
Division 05 - Metals, Structural Metal Framing, Metal Decking.
Division 23 - Heating, Ventilating, and Air Conditioning (HVAC), Facility Fuel Piping, Facility Fuel-Storage Tanks.
Division 31 - Earthwork, Clearing and Grubbing, Grading.
Division 32 - Exterior Improvements, Fences and Gates.
Division 33 - Utilities, Storm Drainage Utilities.

Bidder's List View project details and contacts
Prospective Bidders View project details and contacts
Project Documents
 Engineered Spec Sheet
 Architectural Plans
 Other Documents