Similar Projects
Generator Systems Corrective and Preventative Maintenance Services at MPT
Term Contract
Post-Bid
Owings Mills, MD 21117

Electrician Services
Post-Bid
Salisbury, MD 21804

Electrical Services for 707/211 SHA HQ Complex
Term Contract
Results
$1,000 to $100,000 est. value
Baltimore, MD

Emergency Power System Replacement
Results
Columbia, MD 21045

Rays on the Roof
Pending Verification
$350,000 est. value
Greenbelt, MD 20770

Generator Maintenance
Post-Bid
Salisbury, MD 21802

Reconnect/Install/Disconnect a Generator
Results
Beltsville, MD 20705

Emergency Power Generator Service and Transfer Switches
Post-Bid
Less than $50,000 est. value
Baltimore, MD 21120

Emergency Generator Maintenance Service-HQ
Term Contract
Results
Glen Burnie, MD 21062

Emergency Power Generator Service and Transfer Switches-Churchville Shop
Post-Bid
Less than $50,000 est. value
Churchville, MD 21028

Uninterruptible Power Supply Services
Results
Rockville, MD 20850

Design, Installation and Maintenance-Solar Photovoltaic System at DPW Landscaping Garage Roof
Post-Bid
College Park, MD 20740

William Preston Lane Jr. Memorial Bridge (WPL) Police Building Generator Replacement
Results
$100,001 to $500,000 est. value
Baltimore, MD 21224

Springfield Hospital Center Preventive Maintenance and Load Testing of Fifteen (15) Emergency Generators
Post-Bid
Sykesville, MD

Switch Gear Preventative Maintenance
Results
Cheverly, MD 20785

Last Updated 05/05/2021 04:50 PM
Project Title

Electrical Distribution Transformers

Physical Address View project details and contacts
City, State (County) Hagerstown, MD   (Washington County)
Category(s) Single Trades
Sub-Category(s) Electric
Contracting Method Competitive Bids.
Project Status Results
Bids Due View project details and contacts
Estimated Value $42,000
Plans Available from
Owner View project details and contacts
Architect View project details and contacts
Description

Electrical Ratings shall be: a. Single phase, 60 Hz. b. HV rating shall be 13800GrdY/7970 V without taps, HV BIL = 95 KV. c. LV rating shall be 120/240 V, LV BIL = 30 KV. d. Impedances shall be within minimum and maximum values specified by the CITY (see Diagram A attached). e. Transformers shall meet the United States Department of Energy (DOE) requirements for efficiency as of January 1, 2016. Transformers shall have these characteristics. a. Aerial, conventional design. b. Mineral-oil filled; self cooled, 65?C rise. Transformers shall be shipped complete with oil. c. Aluminum or Copper Windings. d. Stainless Steel Hardware.

Details

Division 26 - Electrical.

Bidder's List View project details and contacts
Prospective Bidders View project details and contacts
Project Documents
 Engineered Spec Sheet
 Architectural Plans
 Other Documents