Similar Projects
Last Updated | 05/27/2022 12:55 PM |
Project Title | Renovation of Hangar 750 |
Physical Address | View project details and contacts |
City, State (County) | Patrick AFB, FL (Brevard County) |
Category(s) | Transportation |
Sub-Category(s) | Aircraft Hangar |
Contracting Method | Competitive Bids. |
Project Status | Results |
Bids Due | View project details and contacts |
Estimated Value | |
Plans Available from | |
Owner | View project details and contacts |
Architect | View project details and contacts |
Description | This project is to repair, modernize and properly configure this 80-year-old hangar facility (B750) to support the current needs of 920th multi-maintenance and administrative functions. Major features of work include - HVAC systems removal and replace. Renovation of restrooms. Remove all unnecessary interior walls to provide a code compliant open-office concept, replacing flooring, stair treads, and ceiling tile. Repaint all interior walls, and replace light fixtures, ducts. Include additional communication/electrical outlets as required. Reconfigure and replace interior utilities such as power, lighting, plumbing and fixtures, HVAC, fire suppression, and communications support. Balance HVAC system upon completion of the project. Install bird netting, install high capacity fans, and paint/seal floor in the bay area. Paint exterior. Provide elevator on north side for code compliance. Replace both the East and West hangar doors. Replace the roof with a standing seam metal roof. Complete the fire hydrant line loop around the hangar footprint. Expand shop footprint to the south by 3,100SF (New Work). Include space in Mech rooms for dehumidification equipment. Total renovation square footage is approximately 71,624SF. Total new work/ expansion square footage is 3,100SF. Notice of Intent to Sole Source Special Notice: The U.S. Army Corps of Engineers Louisville District (USACE) will be soliciting proposals for the Renovation of Hangar 750 for 920 Row at B750 Redstone Road, Patrick Air Force Base, Florida. As part of the construction contract solicitation, USACE intends to include the following sole source requirements: Mechanical – Best Coremax – with Keyway X39Z 1CX7X39Z-2-626 for combinated cores or 1CX7X39Z-1-626 for un-combinated cores are the standard security requirements by the base. Mechanical – Trane – this manufacturer is required as they are the base standard for chiller systems. Fire Protection – Monaco Fire Alarm Panel – Monaco MAAP-X – Fire alarm control panel and transceiver both manufactured by Monaco are required to interface with the Monaco receiving station at the Fire Department. Fire Protection – Det-Tronics Model X3301 Triple –IR (Det-Tronics Eagle Quantum Premier Fire Releasing and Optical Detection System) – this system is required as outlined in the UFC for hangar flame and heat detection. Furniture Fixtures & Equipment (FF&E) - Basis of Design - The following manufactures were used for the Government's basis of design, but equal products can be used: Claridge Products & Equipment, Grainger, Haworth, Tennsco. |
||||||||||||||||||||
Details | ,, 74,724 SF - 1 Aircraft Hangar, Approximately 3,100 SF Addition, 1 Aircraft Hangar, 71,624 SF Renovation.
|
||||||||||||||||||||
Bidder's List | View project details and contacts | ||||||||||||||||||||
Prospective Bidders | View project details and contacts | ||||||||||||||||||||
Project Documents |
Engineered Spec Sheet Architectural Plans Other Documents |