Similar Projects
Tree Removal Services (Bark Beetle)
Term Contract
Bidding
Phoenix, AZ

Grounds Maintenance and Landscaping
Post-Bid
Phoenix, AZ 85016

Landscape Maintenance, Areas 1-4
Post-Bid
Chandler, AZ

Tree Trimming and Removal Services
Term Contract
Results
Phoenix, AZ 85008

Parkway Improvement Districts Landscape Maintenance
Term Contract
Results
Gilbert, AZ 85296

Annual Landscaping Services
Term Contract
Post-Bid
Fountain Hills, AZ 85268

Installation of A Synthetic Turf Fields at Tempe High and Desert Vista
Results
Tempe, AZ 85281

Residential Landscape Services
Term Contract
Post-Bid
Tempe, AZ 85280

Public Housing Irrigation Replacement
Results
Chandler, AZ 85225

Irrigation Replacement - Public Housing
Post-Bid
Chandler, AZ

Landscape Services Water Ranch and Neely Ranch
Term Contract
Results
Gilbert, AZ 85296

Design-Build Services Hayden Lawn Remediation
Post-Bid
Tempe, AZ 85281

Landscape Services for Water Production
Term Contract
Results
Gilbert, AZ 85296

Landscape and Groundskeeping Services
Post-Bid
Maricopa, AZ 85138

S--Provide Weed Control Services
Results
Coolidge, AZ

Reported 08/13/2021 12:00 AM
Project Title

12905B21q0062 - Turf Research Pop-Sprinkler Irrigation System - Maricopa, Az

Physical Address View project details and contacts
City, State (County) Maricopa, AZ 85138 (Maricopa, Pinal Counties)
Category(s) Single Trades
Sub-Category(s) Landscaping/Irrigation
Contracting Method Competitive Bids.
Project Status Request for Quotations
Bids Due View project details and contacts
Estimated Value
Plans Available from Federal Agency
Owner View project details and contacts
Architect View project details and contacts
Description

Project consists of twelve controllable plots of 27’ by 324’ with rotator sprinkler heads installed spaced 27’ apart. Mainline should be 3-inch PVC. First plot is 50 ‘from mainline on concrete pump/filter pad. The 180o sprinklers should emit 1.58 gallons per minute (gpm) and the 90o sprinklers should emit 0.76 gpm at an operating pressure of 30 psi. Water application rate should be 0.48 inch per hour. Existing main line has a flow meter and disc filter. Two-wire valves should be installed in the ground on the east side of the plots (plots run east-west). USDA has existing 5 Hp pump with 110 gpm flow at 32 psi (85 gpm at 42 psi) and an existing dual sand filter and an automated back-flush system and a Baseline 3200 controller and bicoders. This system is an expansion of the first phase of three plots.

Details

Division 32 - Exterior Improvements, Operation and Maintenance of Exterior Improvements, Irrigation, Planting Irrigation, Planting, Planting Preparation, Soil Preparation, Landscape Grading.

Bidder's List View project details and contacts
Prospective Bidders View project details and contacts
Project Documents
 Engineered Spec Sheet
 Architectural Plans
 Other Documents