Similar Projects
Storm Water Drainage Pipe
Term Contract
Bidding
TN

Plumbing Updates
Alteration
Bidding
Livingston, TN 38570

Rehabilitation of a Storm Drain Pipe
Post-Bid
Signal Mountain, TN

Metal Culvert and HP Storm Pipe
Post-Bid
Chattanooga, TN 37400

Storm Drain Replacement at Glengerrie Drive
Results
Less than $14,025 est. value
Lakesite, TN

2020 Red Bank Sewer Rehabilitation
Results
Red Bank, TN

Grove Drive Storm Water System Improvements
Infrastructure
Bidding
Kingsport, TN 37663

Water And Sewer System Improvements
Post-Bid
$200,000 est. value
Pulaski, TN

Storm and Sanitary Sewer Revisions at Lupton City Mill
Results
Less than $598,589 est. value
Chattanooga, TN 37402

Knoxville Municipal Golf Course Drainage
Infrastructure
Bidding
Knoxville, TN 37921

Northfield-Grassland Drive Stormwater Pipe Replacement
Post-Bid
Maryville, TN 37804

Concrete Pathway Installation, Landscaping, Storm Water Structure Modifications, Irrigation System, L.E.D. Pedestrian Lighting, Installation of ADA Compliant Crossing Ramps, Railroad Safety Improvements
Results
Chattanooga, TN

Lochwood Drainage Basin Storm Water System Improvements
Infrastructure
Bidding
Kingsport, TN

Aerial Sewer Creek Crossing Improvements
Post-Bid
Pulaski, TN

Center Street Drainage Outfall (VFW)
Results
Collierville, TN 38017

Reported 05/19/2021 12:00 AM
Project Title

Storm Water Pipe

Physical Address View project details and contacts
City, State (County) Sevierville, TN   (Sevier County)
Category(s) Sewer and Water
Sub-Category(s) Storm/Sewers
Contracting Method Competitive Bids.
Project Status Bidding
Bids Due View project details and contacts
Estimated Value
Plans Available from Agency's Affiliate
Owner View project details and contacts
Architect View project details and contacts
Description

Pipe shall be high density polyethylene pipe with a corrugated exterior and smooth interior for pipe size of 12 to 42 inches (inside diameter) and a profile wall with a smooth interior and exterior for 48 inch inside diameter. Pipe must be constructed from virgin Polyethylene compounds that conform with requirements of cell class 335420C as defined and described in ASTM D3350. The integrally formed smooth waterway shall provide a Mannings “n” value of 0.012.Corrugations for pipe size 4 to 42 inches shall be annular.All pipe and fittings shall conform to AASHTO M294-98 “type S or D” which describes pipe with a smooth waterway.Joints shall consist of a bell and spigot type joint with an O-ring rubber gasket meeting ASTM F477 and placed on the spigot end. At least two corrugations must insert into the bell end.Pipe shall comply with the requirements for test methods, dimensions and markings found in ASHTO Designations M252 and M294

Details

Division 03 - Concrete, Precast Concrete.
Division 33 - Utilities, Storm Drainage Utilities, Storm Utility Drainage Piping, Storm Utility Water Drains, Storm Drainage Structures.

Bidder's List View project details and contacts
Prospective Bidders View project details and contacts
Project Documents
 Engineered Spec Sheet
 Architectural Plans
 Other Documents