Similar Projects
Johnson Hall Solar Array
Term Contract
Post-Bid
Cobleskill, NY 12043

2019 Pole Replacement
Post-Bid
Green Island, NY 12183

Z--528A7-14-715 Renovate Secondary Electrical Distribution
Results
$2,000,000 to $5,000,000 est. value
Syracuse, NY

Proposed Lakeland High School Athletic Fields and Tennis Courts Improvement Contract 2 - Electrical
Results
Shrub Oak, NY 10588

New Climate Control System-West Haverstraw Village Community Center Gymnasium
Post-Bid
West Haverstraw, NY 10993

H--Three Year Electric Study for the Canandaigua VAMC
Results
Canandaigua, NY 14424

Merritt Lighting Upgrade
Post-Bid
$50,000 to $200,000 est. value
Geneseo, NY 14454

Z--528A7-18-708 Replace Obsolete Panelboards
Results
$250,000 to $500,000 est. value
Syracuse, NY

Mechanical, Plumbing and Electrical Work for the Lower Wappinger Creek Community Boat House
Post-Bid
Wappingers Falls, NY 12590

Remove & Replace Batteries in Emergency Lighting Inverter, Farrell Army Reserve Center, Saugerties, NY
Results
$25,000 to $100,000 est. value
Saugerties, NY 12477

Emergency Generator Service/Maintenance at Various Locations
Post-Bid
Mahopac, NY 10541

Z--528A6-19-621 Emergency Power for B76 Chiller
Results
$100,000 to $250,000 est. value
Bath, NY 14810

Electrical Distribution Equipment Testing, Maintenance and Repair
Term Contract
Post-Bid
Albany, NY 12242

J--Testing & PM for Generator Systems - Buffalo/Batavia
Results
$100,000 to $250,000 est. value
Batavia, Buffalo, NY 14215

Electrical Switchgear Testing at Otisville CF
Post-Bid
Otisville, NY 10963

Reported 07/29/2020 12:00 AM
Project Title

Standby Generator

Physical Address View project details and contacts
City, State (County) Rodman, NY 13682   (Jefferson County)
Category(s) Single Trades
Sub-Category(s) Electric
Contracting Method Competitive Bids.
Project Status Bidding
Bids Due View project details and contacts
Estimated Value
Plans Available from Municipal Agency
Owner View project details and contacts
Architect View project details and contacts
Description

Provide and install a Kohler 38RCLB generator, single phase, 120/240v propane fueled generator or equal with a 200A service entrance rated transfer switch and surge protector. Provide and install 60A load shed module (for building siren) Provide and install concrete base, conduits, wiring, terminations, and testing for a complete and usable system. The concrete base shall be a 7-inch poured and reinforced concrete pad at last 5ft. from the building per NFPA 37 Standard for Stationary Combustion Engine Installation All exterior wiring shall be in PVC or flexible liquid tight conduit, and all power wiring shall be copper. Neutral and ground wiring shall be separated and unbonded in the electrical panel and a third-party electrical inspection shall be provided by a licensed electrical inspector. Provide and install gas connections from generator and tie into existing propane lines. (owner shall request larger tank from propane supplier) All gas plumbing shall be black iron pipe and painted medium grey. A flexible gas whip shall be installed at the generator for vibration isolation, and all gas work shall be in accordance with NFPA 54 National Fuel Gas Code standards and NFPA 58 National Liquefied Petroleum Gas Code standards.

Details

Division 26 - Electrical.

Bidder's List View project details and contacts
Prospective Bidders View project details and contacts
Project Documents
 Engineered Spec Sheet
 Architectural Plans
 Other Documents