Similar Projects
BESC Parking Security
Alteration
Results
Portland, OR 97227

Fiber to the Premise Hilight Multi Dwelling Units and Commercial Structured Wiring Work
Term Contract
Post-Bid
$100,001 to $1,000,000 est. value
Hillsboro, OR

Classroom Visual Solutions
Term Contract
Post-Bid
$2,000,000 est. value
Salem, OR

Video Surveillance System Installation
Alteration
Design
Portland, OR 97232

Video Surveillance System (VSS)
Alteration
Bidding
Troutdale, OR 97060

Indefinite Delivery or Indefinite Quantity Classroom Backbone Infrastructure Modernization
Alteration
Results
Portland, OR

HiLight FTTP Construction Phase 2 Public Improvement ITB
Alteration
Bidding
Hillsboro, OR

Wastewater System Scada/Plc On-Call/Support Services
Alteration
Results
Redmond, OR

Last Updated 01/07/2022 05:54 PM
Project Title

Aloha Inn Access Controls

Physical Address View project details and contacts
City, State (County) Aloha, OR   (Washington County)
Category(s) Single Trades
Sub-Category(s) Security/Communications
Contracting Method Competitive Bids.
Project Status Results
Bids Due View project details and contacts
Estimated Value $80,000
Plans Available from
Owner View project details and contacts
Architect View project details and contacts
Description

The Contractor shall design, provide, and install a complete and fully operational key fob readerbased access control system for the project, including 54 tenant units and 6 general building doors. The Access Control System shall be self-contained on premise and not require cloud functionality for management. All Access Control hardware shall be wired and not require batteries. The system shall interconnect with the Front Entry/ Intercom System to allow the Building Manager’s Desk to remotely unlock the front doors. The Contractor shall coordinate with the Elevator Contractor to install fob readers in the elevator cabs and allow for this functionality. All tenant access control doors are to “fail safe” such that they unlock in the case of a power failure, including building entries. System should supply real-time status report of all doors, as well as centralized historical reporting. Existing hotel style mortise lock sets will need to be replaced with durable master keyed lock sets.

Details

Division 27 - Communications, Common Work Results for Communications.
Division 28 - Electronic Safety and Security, Common Work Results for Electronic Safety and Security.