Similar Projects
Reported | 11/16/2021 03:14 PM |
Project Title | Training Facility Update - Burn Rooms |
Physical Address | View project details and contacts |
City, State (County) | GA (Barrow County) |
Category(s) | Government/Public |
Sub-Category(s) | Fire/Police Station |
Contracting Method | Competitive Bids. |
Project Status | No Responses Submitted |
Bids Due | View project details and contacts |
Estimated Value | |
Plans Available from | |
Owner | View project details and contacts |
Architect | View project details and contacts |
Description | Scope of work: To replace and update existing burn rooms in containers with materials consistent with the following. Burn rooms shall be constructed using high temperature insulation with a minimum of a 2000 degree Fahrenheit rating. Insulation shall be enclosed within a frame and covered with a minimum of 11 gauge sheet metal. All metal used in burn room shall be American steel. Welds and door metal shall be drilled and plug welded to insure durability of walls under high temperature conditions. All wood shall be removed from container and covered with a minimum 11 gauge metal and a layer of 1’ square common paver bricks. Chain shall be used on the walls and ceilings to hold commons sheet lumber. Chain shall be minimum 5/16”. Side walls and ceiling shall easily accept full sheets of 4x8 of sheet lumber without requiring any cuts or notching. A cable controlled vent system shall be re-installed at the edge of the insulation exterior of the burn room. Interior doors shall be installed on burn rooms to simulate a closed or open door concept, doors shall be constructed of heavy gauge steel capable of withstanding high heat conditions. Interior Doors shall be able to be locked, open and shut freely utilizing a closing mechanism. One exterior door shall be installed on the first floor burn room, capable of withstanding high heat conditions. One exterior burn room window shall be installed in both burn rooms, constructed of materials consistent with door materials and capable of withstanding high heat conditions. Exterior doors and windows shall be able to open and close freely and be able to be locked into positions of open and closed. To add a set of exterior stairs to existing burn building. Stairs should extend from ground level to the fourth floor with access to every floor utilizing existing container doors. Platforms are to be installed on every floor with stairs. Stairs should be constructed of steel and painted. Stairs should be built to customer’s photos and vision. |
||||||||||||||||||
Details | Fire/Police Station, Renovation.
|
||||||||||||||||||
Bidder's List | View project details and contacts | ||||||||||||||||||
Prospective Bidders | View project details and contacts | ||||||||||||||||||
Project Documents |
Engineered Spec Sheet Architectural Plans Other Documents |