Similar Projects
Expo Roof Repairs Phase 1 - City of Portland
Alteration
Conception
$350,000 est. value
Portland, ME

Hangar 1 Roof Replacement Project
Renovation
Sub-Bidding
$500,000 CJ est. value
Bangor, ME 04401

Waterville Armory Roof Repair Project
Renovation
Sub-Bidding
$500,000 CJ est. value
Waterville, ME 04901

Penobscot Hall Reroofing
Alteration
Post-Bid
Orono, ME 04473

Replacement of Lincoln School Asphalt Roof
Alteration
Post-Bid
Auburn, ME

Fire Station Roof
Alteration
Results
North Haven, ME

Dorothea Dix Psychiatric Center Roof Replacement
Alteration
Results
$1,861,900 est. value
Bangor, ME 04401

Roof Replacement Engineering Building and Pilot Plant
Renovation
Sub-Bidding
$255,000 CJ est. value
Millinocket, ME 04462

Design/Build A Frame Roof and Enclosure for Digital Sign
Infrastructure, Alteration
Post-Bid
Lyman, ME

Roof Preventative Maintenance and Repair Services
Alteration
Results

Brooke Dining Hall Roof Repair, Darling Marine Center
Renovation
Sub-Bidding
$68,000 CJ est. value
Cumberland Center, ME 04021

Lengyel Hall Roof Replacement
Alteration
Post-Bid
Orono, ME

Municipal Building Re-Roofing
Alteration
Results
Boothbay Harbor, ME 04538

Roof Restoration
Alteration
Post-Bid
$900,000 est. value
Auburn, ME 04210

Sagadahoc Courthouse Tower Roof Repairs
Alteration
Results
Bath, ME 04530

Last Updated 05/12/2023 09:39 AM
Project Title

Hancock County Middle Roof Project

Physical Address View project details and contacts
City, State (County) Ellsworth, ME 04605   (Hancock County)
Category(s) Single Trades
Sub-Category(s) Roofing
Contracting Method Competitive Bids
Project Status Contract Award, Construction start expected April 2023
Bids Due View project details and contacts
Estimated Value $57,000 [brand] Estimate
Plans Available from Agency's Affiliate
Owner View project details and contacts
Architect View project details and contacts
Description

The County of Hancock hereby solicits bids for the repair and replacement of the "Hancock County Middle roof and Accessory roofs" (Associated roofs are to be the Elevator tower roof and the Court clerks ramp roof). The work will take place at the Hancock County Courthouse located at 50 State St Ellsworth Maine 04605. This project will be regularly inspected by county officials and demands high quality workmanship. Work can commence as early as April 15, 2023 and completed by September 30, 2023. The County of Hancock reserves the right to ask questions of any party post-bid opening, and select or reject any bid, all actions without cause or reason. Please contact the Hancock County Facilities Director at (207) 667-1409 if there are questions. a. The existing roof membrane shall be removed along with any unnecessary roof penetrations. Any openings shall be sealed and insulated as to become a flush surface consistent with the rest of the roof surface. The roof, and accessory roofs, shall be removed and disposed of in a manner that is safe and efficient. The work shall be performed by licensed qualified personnel, and shall include adequate preparations for the installation of the proposed repairs and resurfacing. Unexpected damage shall be repaired on a time and material basis, approved by the owner b. The tapered roof layout shall include a minimum of 2 layers of 2.5 inch insulation adhered to the deck and shall direct surface water to the appropriate drain. c. The membrane shall be of first quality EPDM, a minimum of.060 thickness or equivalent, and shall be installed per manufacturer specifications. d. The Membrane shall be inspected and approved for full warrantee e. All penetrations shall be flashed and sealed with material that provides the same or similar warrantee as the newly installed membrane. The use of pitch pockets and or "witches hats" shall be determined to provide the most durable finish. Minimum flashing thickness is to be .032 f. Sidewall and parapet terminations shall be of aluminum flashing with a minimum.032 thickness and shall be installed to provide full warrantee and durability g. All work shall conform to all applicable building codes, and in the absence of such, shall be consistent with manufacturer's recommendations, industry standards, and/or "best practices".

Details

Division 07 - Thermal and Moisture Protection, Dampproofing and Waterproofing, Thermal Protection.

Bidder's List View project details and contacts
Prospective Bidders View project details and contacts
Project Documents
 Engineered Spec Sheet
 Architectural Plans
 Other Documents