Similar Projects
On-Call Cathodic Protection Services
Infrastructure
Bidding
Denver, CO 80249

Industrial Hygiene
Term Contract
Sub-Bidding
Denver, CO 80202

Portable Sanitation Services
Post-Bid

On Call Tank and Monitoring Services
Post-Bid
CO

World-Wide Water Storage Tank Remediation
Term Contract
Results

Nine-Mile Driver Relief Station Replacement
Results
Denver, CO

Maintenance Services for Wynkoop Plaza for the Regional Transportation District
Post-Bid
Denver, CO

Z--Bgndrf Glass Fused to Steel Storage Tanks Maintenance and Repairs
Results

Pressure Washing of City-Owned Garages
Alteration
Post-Bid
Denver, CO 80202

CTF TCF Water Pump Skid Repl. Dq1 GC CMS165046
Results
Less than $60,000 est. value

Z--Romo/239689, Moraine Park Campground and HQ Utilities-GAOA
Term Contract
Post-Bid
$10,000,000 est. value
Estes Park, CO 80517

CTF ECCPC South Pump Station Roof DQ1 GC CMS164761
Renovation
Results
$150,000 est. value
Gunnison, CO 81230

Window Washing Services for Auraria Higher Education Center
Alteration
Post-Bid
Denver, CO 80204

Statewide Pest Control
Results

Biohazard/ Medical Waste Disposal
Infrastructure
Post-Bid
Denver, CO

Last Updated 07/26/2022 05:03 PM
Project Title

RFQ - Clermont Underground Storage Tank Inspection and Testing - 554

Physical Address View project details and contacts
City, State (County) Denver, CO 80220   (Denver County)
Category(s) Sewer and Water, Single Trades
Sub-Category(s) Lift and Pump Stations, Service/Term Contracts, Storage/Water Tanks
Contracting Method Competitive Bids
Project Status Obtained from a credible source, Awaiting verification, Construction start expected January 2023
Bids Due View project details and contacts
Estimated Value
Plans Available from Agency's Affiliate
Owner View project details and contacts
Architect View project details and contacts
Description

As of July 22, 2022, a contractor has not been selected. *The closed solicitation has been included below for reference: REQUEST FOR INFORMATION / SOURCES SOUGHT SYNOPSIS The Department of Veterans Affairs Network Contracting Office (NCO) 19, Rocky Mountain Acquisition Center (RMAC) is issuing this sources sought notice as a means of conducting market research to identify parties having an interest in, and the resources to support this requirement for Fuel Storage Tank Maintenance and Inspection at Clermont for the Denver VA Medical Center located at 1055 Clermont Street, Denver, CO 80220. The result of this market research will contribute to determining the method of procurement. The applicable North American Industry Classification System (NAICS) code assigned to this procurement is 237120 Oil and Gas Pipeline and Related Structures Construction. This is a request for information and sources only, which may or may not lead to a future solicitation! This is not a solicitation. This request for capability information does not constitute a request for proposals; submission of any information in response to this market survey is purely voluntary; the government assumes no financial responsibility for any costs incurred. Contractor shall provide all labor, parts, supplies and equipment necessary to perform Fuel Storage Tank Maintenance and Inspection Services shall include but are not limited to: BACKGROUND. The Eastern Colorado Health Care System (ECHCS) is committed to the protection of the environment and compliance with all applicable environment protection laws. The old Denver VA Medical Center at 1055 Clermont Street, Denver CO 80220 facility has an Underground Fuel Storage Tank management program in place to address monitoring, record-keeping requirements and regulations, procedures and organizational mechanisms designed to prevent or limit accidental release of Petroleum, Oil and Lubricates (POL) to surface water, groundwater, or soils. The fuel storage tank system has underground storage tanks (UST), above storage tanks (AST), day tanks, and associated fuel supply piping system at 1055 Clermont Street, Denver CO, 80220. RMRVAMC has a need for the inspection and testing of this Government owned fuel storage tank system consisting of 1 EA 4,000 gallon UST (underground storage tank), 1 EA 500 gallon vaulted AST (aboveground storage tank), 4 EA 20,000 gallon UST, and a 2,800 gallon bermed secondary containment system. The fuel storage and distribution system must be inspected, drained, monitored monthly, bi-monthly Cathodic Protection Inspection, and inspected again at either the 1-year mark or prior to the sale of the property, whichever occurs first. SCOPE. The contractor shall provide all personnel, equipment, supplies, PPE, transportation, tools, materials, management services necessary to drain the system, properly dispose of the drained substance, perform inspections and testing to both the USTs and ASTs on the Clermont campus, monitored monthly, bi-monthly cathodic protection inspections, and provide all reports to the VA within 5 business days of the site visit as required in this Statement of Work (SOW). The contractor shall perform to the standards in this contract. The Contractor shall abide by all laws, rules, and regulation applicable to fuel storage tanks operations. All service must comply with the SOW and all applicable federal, state, county, and fire marshal laws and regulations. BASED ON THE RESPONSES TO THIS SOURCES SOUGHT NOTICE, THIS REQUIREMENT MAY BE SET-ASIDE FOR SMALL BUSINESSES OR PROCURED THROUGH FULL AND OPEN COMPETITION, and multiple awards MAY be made. Telephone inquiries will not be accepted or acknowledged, and no feedback or evaluations will be provided to companies regarding their submissions. SUBMISSION INSTRUCTIONS: If your organization can provide these services and is interested in this opportunity, please respond to Erica Cassidy, Contract Specialist, Department of Veterans Affairs, NCO 19, 6162 South Willow Drive, Suite 300, Greenwood Village, Colorado 80111 or via e-mail at Erica.Cassidy@va.gov and NCO19Services1@va.gov with a statement describing your capabilities. The capability statement shall include a point of contact, complete mailing address, telephone number, email address, and state the company s business size status and should address this specific requirement, with appropriate documentation supporting claims of organizational and staff capability. Please be as thorough as possible in your submission. Requests for copies of a solicitation will not be honored or acknowledged. The deadline for responses is Wednesday, July 20, 2022 at 12:30 PM Mountain Time. The method of contractor selection has not been determined at this time. *Project information, including timeline and contacts, has been obtained through public sources. The content management team continues to pursue additional details; however, the contact(s) listed have yet to disclose or confirm any information. Inquiries should be directed to the contact(s) listed.

Details

Division 00 - Procurement and Contracting Requirements.
Division 01 - General Requirements.
Division 02 - Existing Conditions, Subsurface Investigation.
Division 03 - Concrete, Concrete Reinforcing, Cast-in-Place Concrete.
Division 04 - Masonry.
Division 05 - Metals, Structural Metal Framing, Metal Decking.
Division 06 - Wood, Plastics, and Composites.
Division 07 - Thermal and Moisture Protection.
Division 08 - Openings.
Division 09 - Finishes.
Division 10 - Specialties, Signage, Toilet, Bath, and Laundry Accessories, Fire Protection Specialties, Fire Extinguishers, Storage Specialties.
Division 11 - Equipment.
Division 12 - Furnishings.
Division 14 - Conveying Equipment, Scaffolding.
Division 21 - Fire Suppression.
Division 22 - Plumbing.
Division 23 - Heating, Ventilating, and Air Conditioning (HVAC), Facility Fuel Piping, Facility Fuel-Storage Tanks.
Division 26 - Electrical.
Division 27 - Communications, Data Communications, Voice Communications, Audio-Video Systems.
Division 28 - Electronic Safety and Security.
Division 31 - Earthwork, Clearing and Grubbing, Grading.
Division 32 - Exterior Improvements, Fences and Gates, Turf and Grasses.
Division 33 - Utilities, Common Work Results for Utilities, Water Utility Distribution Equipment, Water Utility Pumping Stations, Wastewater Utility Pumping Stations, Sanitary Utility Sewerage Force Mains, Storm Drainage Utilities.
Division 40 - Process Integration, Water Process Piping.
Division 45 - Industry-Specific Manufacturing Equipment.
Division 46 - Water and Wastewater Equipment.

Bidder's List View project details and contacts
Prospective Bidders View project details and contacts
Project Documents
 Engineered Spec Sheet
 Architectural Plans
 Other Documents