Similar Projects
Replace Two HVAC Systems located in Building 1001
Design
$1,000,000 to $5,000,000 est. value
Fort Hood, TX

HVAC Control System Replacement Project
Results
Pflugerville, TX

HVAC Replacement Project
Results
Less than $301,000 est. value
TX

OCB Chiller Maintenance Service
Results
Houston, TX

Chiller Replacement
Results
$500,000 to $1,000,000 est. value
Midland, TX 7971

Emergency HVAC Replacement
Results
Austin, TX

4th Floor Renovations and AHU Replacement
Results
Fort Worth, TX

Cooling Tower Maintenance, Inspections, and Other Services
Results
San Antonio, TX

Chiller Replacement at Lyndon B.Johnson Hospital
Results
Less than $4,470,040 est. value
Houston, TX

Remove and Replace Duct Insulation
Results
Houston, TX

HVAC Optimization and Replacement
Results
Sachse, TX 75048

Vehicle Exhaust Extraction System
Results
Houston, TX 77000

FWCC Air Handler Unit Replacement
Results
$845,000 est. value
Fort Worth, TX

HVAC Unit Replacement - BOT
Results
$111,800 est. value
Huntsville, TX 77320

Head Start HVAC Upgrades
Results
$240,000 est. value
San Antonio, TX

Reported 12/15/2018 12:00 AM
Project Title

HVAC Repair

Physical Address View project details and contacts
City, State (County) Port O'Connor, TX 77982   (Calhoun County)
Category(s) Single Trades
Sub-Category(s) HVAC
Contracting Method Competitive Bids.
Project Status Request for Quotations
Bids Due View project details and contacts
Estimated Value
Plans Available from Federal Agency
Owner View project details and contacts
Architect View project details and contacts
Description Provide all labor, materials, equipment, transportation and supervision necessary to complete the following work. Major items of work shall include the following: ANT Team Building HVAC units (2 total); Remove and replace: (1) Lennox condensing unit with protective coating- Model no. 13ACX-024-230-10 (equivalent or better). (1) Lennox air handling unit compatible with item 1.1 (equivalent or better) . (1) Goodman condensing unit with protective coating-Model no. SSX140241AC; Unit is elevated approximately five (5) feet above grade. (equivalent or better). (1) Goodman air handling unit compatible with item 1.3 (equivalent or better) . (2) reusable air filters. Engineering Shop; Remove and replace: (1) RHEEM condensing unit with protective coating- Model no. RQNL-B024JK 000; Unit is located on roof of two (2) story building. (equivalent or better). (2) reusable air filters. Station Building HVAC system (2 air handling units): Complete air balance. Foam and seal returns. General servicing and inspection of system.
Details
Division 23 - Heating, Ventilating, and Air Conditioning (HVAC), Instrumentation and Control for HVAC, HVAC Air Distribution, Central HVAC Equipment.
Bidder's List View project details and contacts
Prospective Bidders View project details and contacts
Project Documents
 Engineered Spec Sheet
 Architectural Plans
 Other Documents