Similar Projects
Perry-Paige Smoke/Fire Damper Replacement
Alteration
Bidding
Tallahassee, FL 32307

Building Fire Alarm Service
Term Contract, Alteration
Bidding
FL

Fire Stations 36, 64 and 65
Post-Bid
Jacksonville, FL

Upgrade Fire Protection at Rotation, Processing, and Surge Facility (RPSF) at Kennedy Space Center, Florida
Post-Bid
$1,000,000 to $5,000,000 est. value
Cape Canaveral, FL 32899

69--Surface Fire Fighting Trainer Smoke/Fog Generation System
Results
Mayport, FL - Newport, RI - Norfolk, VA

Z--Sources Sought Notice for Design-Build Fire Protection Systems in Bldgs A-4171, 1350, and 1351 and Afff Systems in Bldgs A-981 and A-131 at Naval Air Station Key West, FL
Results
$5,000,000 to $10,000,000 est. value
Key West, FL 33040

Hangar 68 Fire Suppression and Renovation
Renovation - 80,000 SF
Construction
$5,000,000 to $10,000,000 est. value
Eglin AFB, FL 32542

Fort Coombs Armory New Automatic Fire Sprinkler and Paint Stabilization
Alteration
Bidding
Apalachicola, FL 32320

Patrick AFB Fire Extinguisher Services
Post-Bid
Patrick AFB, FL 32925

MIA - Terminal H FL2 Area A - Smoke Evacuation System
Results
$832,796 est. value
Miami, FL

Fire Protection System Services
Alteration
Bidding
FL

Fire Alarm Monitoring at Paradise Trail
Post-Bid
Clearwater, FL 33755

4931--Fire Alarm Control Center Upgrade and Fire Alarm Combination for Building 7 and 12
Results
Palm Beach Gardens, FL 33410

Fire Extinguisher Service and Maintenance
Term Contract
Post-Bid
Macclenny, Olustee, Sanderson, FL

H342--FY20: Fire Suppression Testing
Results
Gainesville, FL 32608

Reported 02/17/2022 12:00 AM
Project Title

FPR ATCT Fire Alarm System Replacement

Physical Address View project details and contacts
City, State (County) Fort Pierce, FL   (Saint Lucie County)
Category(s) Single Trades
Sub-Category(s) Fire Protection
Contracting Method Competitive Bids.
Project Status Accepting Letters of Interest
Bids Due View project details and contacts
Estimated Value
Plans Available from Federal Agency
Owner View project details and contacts
Architect View project details and contacts
Description

1. Installing a new fire alarm system side-by-side to the existing Simplex 4100U fire alarm system. The existing system shall remain fully operational until the new system is installed, inspected, tested, commissioned and accepted. 2. Connecting and interfacing the new fire alarm system to the existing emergency control function interface device circuits, once the cutover plan is approved. 3. Removing and replacing the existing transient voltage surge suppression. Devices (TVSS) and installing new TVSS’s on fire alarm system equipment and circuits in accordance with FAA requirements. 4. Conducting a 100% acceptance test in accordance with NFPA 72, National Fire Alarm and Signaling Code by functionally testing / operating every initiating device, notification appliance and emergency control function interface device for proper operation and annunciation. 5. Removing and demolishing off-site the existing fire alarm system equipment, conduit and wiring that is not reused. 6. Permanently securing smoke damper louvers in the open position for the two fire/smoke dampers installed as part of the stair pressurization system shaft located on the Intermediate Level 1 of the ATCT. 7. Firestopping all new penetrations made to accommodate new or removed conduits, wireways or other equipment, so that the rating of the enclosure is maintained. 8. Painting and patching in accordance with the Contract Documents to the satisfaction of the FAA.

Details

Division 21 - Fire Suppression.
Division 28 - Electronic Safety and Security, Fire Detection and Alarm.

Bidder's List View project details and contacts
Prospective Bidders View project details and contacts
Project Documents
 Engineered Spec Sheet
 Architectural Plans
 Other Documents