Similar Projects
Walk In Shower and Roof Repair -Adair County
Renovation
Design
$20,000 CJ est. value
Stilwell, OK 74960

Roof Repairs/replacements Bethany
Renovation
Sub-Bidding
$134,000 CJ est. value
Bethany, OK 73008

Duncan Public Schools District Roofing Repairs
Renovation
Sub-Bidding
$500,000 CJ est. value
Duncan, OK 73533

TAC Roof Program B9001 - Multiple Award Task Order Contract (MATOC)
Post-Bid
$2,000 to $15,000,000 est. value

TAC Roof Program B9001 - Multiple Award Task Order Contract (MATOC)
Post-Bid
$2,000 to $15,000,000 est. value

National Roofing Program (Nrp) - Roofing Construction Project #13
Term Contract
Results
$500,000 to $1,000,000 est. value
Ada, OK

Repair East & West Lean To Roof B187
Alteration
Results
Enid, OK 73703

Removal and Replacement of the Laminated Composition Shingle Roof With Felt of the Heavener Public Library
Renovation
Construction
$420,000 CJ est. value
Heavener, OK 74937

Tulsa Public Schools Roofing at Various Sites
Alteration
Post-Bid
$2,100,000 est. value
Tulsa, OK

Vance Air Force Base Repair Roof
Term Contract
Results
$250,000 to $500,000 est. value
Enid, OK 73703

Sheriff Department Roof
Alteration
Post-Bid
Miami, OK 74354

Roof Repairs
Alteration
Results
McAlester, OK 74501

Roof Replacement Lacy Park Community Center
Alteration
Post-Bid
Tulsa, OK 74106

Justice Center Roof Replacement
Alteration
Results
Sapulpa, OK 74066

Complete Roof Repair
Alteration
Post-Bid
OK

Last Updated 05/16/2023 03:39 PM
Project Title

State of Oklahoma Roof Asset Management Program Area 3

Physical Address View project details and contacts
City, State (County) Oklahoma City, OK 73102   (Oklahoma County)
Category(s) Single Trades
Sub-Category(s) Roofing
Contracting Method Competitive Bids
Project Status Bidding, Construction start expected July 2023
Bids Due View project details and contacts
Estimated Value $3,000,000 [brand] Estimate
Plans Available from Agency's Affiliate
Owner View project details and contacts
Architect View project details and contacts
Description

CAP Project Number: CAP000745 Project Name: State of Oklahoma Roof Asset Management Program Project Location: Area 3 per map in Project Manual Using Agency: OMES/CAM/ CPRES Bid Documents Available: April 4, 2023 Fee to Submit Online Bid: See Website Contact Person(s): Manny Sauviller - manny.sauviller@ omes.ok.gov If the bid exceeds $100,000, a cashier's check, a certified check or surety bid bond in the amount of five percent (5%) of the total bid shall accompany the sealed bid of each bidder. Security checks will be returned to all but the three lowest bidders after the bid opening. The three lowest bid securities will be retained until the contract is awarded. SCOPE OF WORK/SUPPLEMENTARY CONDITIONS Pursuant to the provisions of O.S. 61 and Title 260 Office of Management and Enterprise Services, Chapter 60 Construction, Planning, and Real Estate Rules, et seq.,: All installed roofing systems must meet the Code and Regulatory Requirements and Recommendations of the most current edition of: 1. The International Code Council (all Codes) including the International Building Code and its References, for example ANSI-SPRI ES-1 certification requirements. 2. All adopted Codes of the Oklahoma State Fire Marshall 3. All recommendations of the National Roofing Contractors Association, (NRCA) 4. Sheet Metal and Air Conditioning Contractor's National Association, (SMACNA) 5. All requirements of the State of Oklahoma Roofing Program and the State of Oklahoma Roof Warranty, Roofing System Manufacturer's Warranty, (RSMW) 6. All applicable American Society for Testing and Materials, (ASTM) Standards, (partial list below) 7. The requirements of U.L. 790 and U.L. 580 8. FM Global Approval Standards 4450, 4470, 4471, 4435, 4451, and 4454 9. All applicable FM Loss Prevention Data Sheets, including FM Data Sheets 1-34, 1-28, 1-29, and 1-49 The State of Oklahoma Has Adopted the International Building Codes of 2018 with revisions. These apply. Excerpted from the: May 2007 -- Factory Mutual Approval Guide All installed roofing systems provided as roofing renovations through the use of this Roofing Maintenance Contract must be FM Approved Roof Constructions. Continued approval is based upon production or availability of the product as FM Approved, the continued use of acceptable quality control procedures, satisfactory field experience, and compliance with the terms stipulated in the Approval Agreement. The roof assemblies shown (in the current Factory Mutual Approval Guide/Roof Nav Database) are FM Approved only when assembled as listed for each specific cover, insulation, fastener, deck or structural substrate. Their compatibility with other roofing components within the construction is the responsibility of the listed manufacturer, who should be consulted prior to their use. Their performance is extremely dependent upon the substrate to which the system is attached or anchored. Corner and Perimeter Enhancements: The FM Approved roof assemblies have been evaluated for exposure to wind loads in the field (interior) of the roof. The wind uplift loads acting at the roof corners and the roof perimeter are generally higher than the load acting in the field of the roof. To compensate for these higher loads, enhancements must be made for the securement of all components in the roof assembly. These enhancements are discussed in detail in FM Global Property Loss Prevention Data Sheets 1-28, 1- 29 and 1-31. Roof Decks: For securement requirements of the roof decking for minimum Class 1-60 wind uplift rated roofs, refer to FM Global Property Loss Prevention Data Sheet 1-28. It is understood that the Contractor(s) awarded a contract will comply with the most stringent industry-standard construction Contact Person(s) for Questions: Manny Sauviller - manny.sauviller@omes.ok.gov

Details

Division 07 - Thermal and Moisture Protection, Dampproofing and Waterproofing, Thermal Protection.

Bidder's List View project details and contacts
Prospective Bidders View project details and contacts
Project Documents
 Engineered Spec Sheet
 Architectural Plans
 Other Documents