Similar Projects
Indefinite Delivery/Indefinite Quantity Electronic Security Systems (ESS) 7th Generation
Term Contract
Design
Less than $675,000,000 est. value

Indefinite Delivery/Indefinite Quantity Electronic Security Systems (ESS) 7th Generation
Term Contract
Design
Less than $675,000,000 est. value

Allen Water Treatment Plant Instrumentation and Control Services
Term Contract
Bidding
Englewood, CO 80110

J061--Covid 19 Emergency Department Shore Power Service
Post-Bid
Aurora, CO

Miracle-Ear Hearing Aid Center
Alteration
Post-Bid
Denver, CO 80231

On-Call Emergency Generator/Transfer Switch Maintenance and Rental
Results
Brighton, CO 80601

I-76 & Bromley Luminaire Underground Rewire
Results
$200,000 to $300,000 est. value
Brighton, CO

Z1dz--T1/ Project 554-22-136 Relocate Power for Patient Transport Cart Chargers (Va-22-00023703)
Term Contract
Design
$50,000 to $100,000 est. value
Aurora, CO 80045

Scissor Lifts
Alteration
Post-Bid
Aurora, CO

Eaton, Cutler Hammer, and Key Stone Electrical Equipment and Parts
Term Contract
Results
$60,000 to $70,000 est. value
Aurora, CO 80012

Switchgear Testing and Maintenance
Alteration
Post-Bid
Aurora, CO

Robertsdale Solar Project
Results
Aurora, CO

Government Center Switch Upgrade
Alteration
Post-Bid
Brighton, CO

Misc. Electrical and Lighting
Results
Brighton, Denver, CO 80216

UPS4 Battery Replacement
Alteration
Post-Bid
Denver, CO

Last Updated 04/27/2022 11:34 AM
Project Title

Electrical Switchgear Maintenance BWPF

Physical Address View project details and contacts
City, State (County) Aurora, CO 80016 (Adams, Arapahoe Counties)
Category(s) Single Trades
Sub-Category(s) Electric
Contracting Method Competitive Bids.
Project Status Results
Bids Due View project details and contacts
Estimated Value
Plans Available from
Owner View project details and contacts
Architect View project details and contacts
Description

The switch gear at Binney Water Purification Facility (BWPF) is the framework used for managing, protecting and isolating electrical circuits and equipment and includes things such as disconnect switches, fuses, and circuit breakers. The switch gear is designed to detect faults in the electrical system as BWPF and allows generators and other electrical equipment to switch on and off preventing service interruption or damage to equipment. Malfunctioning switch gear can cause fires and explosions resulting in injury or facility closure. Testing, inspection and planned maintenance help reduce the risk of injury and potential system failures. Electrical Contractor best practice recommendations include performing switch gear testing and maintenance every three years. However, electrical switch gear maintenance has never been performed at Binney Treatment Plant. This SOW and proposed testing, inspection and maintenance of the switch gear requires a system outage and must wait until BWPF is offline for annual maintenance. The next planned maintenance shutdown for BWPF is in May 2022.

Details

Division 26 - Electrical, Low-Voltage Switchgear.

Bidder's List View project details and contacts
Prospective Bidders View project details and contacts
Project Documents
 Engineered Spec Sheet
 Architectural Plans
 Other Documents