Similar Projects
Last Updated | 07/10/2023 06:32 AM |
Project Title | 60 Ton Chiller |
Physical Address | View project details and contacts |
City, State (County) | New Orleans, LA 70112 (Orleans County) |
Category(s) | Single Trades |
Sub-Category(s) | HVAC |
Contracting Method | Competitive Bids |
Project Status | Sub-Bidding, Construction start expected September 2023 |
Bids Due | View project details and contacts |
Estimated Value | $168,766 [brand] Estimate |
Plans Available from | Agency's Affiliate |
Owner | View project details and contacts |
Architect | View project details and contacts |
Description | 60 Ton Chiller Installation Dates are subject to changes via an addendum posted by the Bureau of Purchasing on the City's supplier portal. The requested SLDBE Contract Goal is 18.22%. The City of New Orleans strongly encourages minority-owned and women-owned businesses, socially and economically disadvantaged businesses and small businesses to respond to this solicitation, or to participate in subcontracting opportunities pursuant to this solicitation. Chiller Replacement Project: 1. Mechanical Installation i) Demolition and removal of the existing McQuay Chiller 60 Chiller (only one). Recover refrigerant from one (1) failed chiller 60 ton, disconnect electrical and chill water piping from one existing 60-ton chiller, Remove of existing piping between isolation valves and chillers. ii) Receive, Store, and Setting/Rigging of the new equipment. iii) Piping and Insulation of New Chilled water lines and bleed air from 60-ton chiller. iv) Supply and Return piping to be insulated to match existing chilled water lines. v) Contractor will remove rubbish and clean/pick up debris daily. vi) Work performed by Contractor or its subcontractors will comply with all applicable Federal, State, and local codes and standards. vii) 60 Ton Air-Cooled Chiller: CGAM060A2 with coated condenser coils. (1) Startup Included - Trane Service must start equipment for warranty to be honored. (2) 208 volt 3 phases. (3) Full factory refrigerant charge (HFC-410A). (4) Refrigerant isolation valves (discharge valve). (5) Factory installed flow switch - set point 60 cm/sec. (6) Grooved pipe connection. (7) Factory insulation 0.75". (8) Wide ambient (0 to 125F/-18 to 52C). (9) Microchannel Complete Coat Condenser Coil. (10) Across the line starter/direct on line. (11) Single point connection main line unit power-ancillary items require other power. (12) Enclosure type UL 1995 rated for outdoor applications with Default A short circuit rating. (13) Elastomeric isolators with water strainer factory installed. (14) Super quiet acoustical package standard. (15) Architectural louvered panels. (16) Five (5) year complete unit Parts, Labor and Refrigerant warranty 2. Electrical Installation i) Disconnect existing chillers. ii) Install new seal tight and wire rated for 300 amp. iii) Make terminations in new chillers and existing disconnects. iv) Supports and miscellaneous material. |
||
Details |
|
||
Bidder's List | View project details and contacts | ||
Prospective Bidders | View project details and contacts | ||
Project Documents |
Engineered Spec Sheet Architectural Plans Other Documents |