Similar Projects
Last Updated | 08/12/2021 07:52 AM |
Project Title | Utility Relocation in Advance of the TxDOT FM 455 Improvements |
Physical Address | View project details and contacts |
City, State (County) | Sanger, TX (Denton County) |
Category(s) | Sewer and Water |
Sub-Category(s) | Sanitary Sewers, Water Lines |
Contracting Method | Competitive Bids. |
Project Status | Results |
Bids Due | View project details and contacts |
Estimated Value | |
Plans Available from | |
Owner | View project details and contacts |
Architect | View project details and contacts |
Description | The major water distribution improvement items to be furnished and installed are 10,345LF of 12" dia. PVC (DR 18) constructed via Open Cut (OC) and 1,890LF PVC Water Carrier Pipe (DR 18) will be inserted in 18" Steel Casing, 1,195LF of 18" Steel Casing pipe constructed via OC and 1,325LF of 18" Steel Casing constructed via Other Than Open Cut (OTOC), 2,360LF of 8" dia. PVC (DR 18) constructed via OC and 455LF of 8" PVC Water Carrier Pipe (DR18) inserted in 12" Steel Casing, 320LF of 12" Steel Casing Pipe by OC, BOLF of 12" Steel Casing by OTOC, 865LF of 2" PVC (sch. 80) constructed via OC, 28 -12" resilient seat gate valves, 11 - 8" resilient seat gate valves, 21 - 6" resilient seat gate valves, 1 - flush hydrants, 20- fire hydrants assembly, 30 - Water Service Reconnections, 18 - Water Meter Box Relocations, Various Ductile Iron Tees, Bends, Fittings and Related Appurtenances and the removal of 9.408LF of various size water pipelines. The major sewer collection system items to be furnished and installed are 790LF of 8" PVC SOR 26 constructed via Open Cut (all depth). 1.494LF of 12" PVC SOR 26 by Open Cut (0-8' deep), 1,972LF of 12" PVC SOR 26 by Open Cut (8'- 16' deep), 210LF of 12" PVC SOR 26 by Open Cut (>16' deep). 710LF of 12" PVC SDR 26 Carrier Pipe inserted in an 18" Steel Casing, 1,530LF of 12" HOPE DR17 Pipe Burst Method, BOLF of 24" PVC SOR 26 constructed Open Cut (6' to 12' deep) , 24" PVC DR 26 Carrier Pipe inserted in a 36" Steel Casing, 55LF of 36" Steel casing Open Cut (8' to 12' deep). 35LF of Steel Casing constructed via Other Than Open Cut (8' to 12' deep) , 22- 4' Dia. Standard SSMH, 2- 4' dia. Eccentric SSMH, 2-5' Dia Standard SSMH, 4- 5' Eccentric SSMH, 33.3LF Extra Depth 4' Dia SSMH, 48.7LF Extra Depth 5' Dia SSMH, 2- Rehabilitate Exist. SSMH, 6- Remove Existing SSMH, 2,835 LF- Remove existing sewer pipelines (various size). 22LF of Curb and Gutter Replacement, 205LF of Fence Repair/ Replace, Various Cut & Plug water and sewer pipelines, clay dam, Geotextile Fabric Liner, Concrete Encasement and miscellaneous items. |
||||
Details |
|
||||
Bidder's List | View project details and contacts | ||||
Prospective Bidders | View project details and contacts | ||||
Project Documents |
Engineered Spec Sheet Architectural Plans Other Documents |