Similar Projects
Contract for the Purchase of a Submersible Pump
Post-Bid
San Antonio, TX

Well Plugging and Related Services: Padre Island National Seashore
Post-Bid
Austin, TX 78701

Construction of a New Water Well and Related Improvements
Results
TX

Plugging Abandoned Water Well
Results
$1,320 est. value
Irving, TX

Repair/Recondition One 50,000 GPM Vertical Centrifugal Water Pump (P-203)
Post-Bid
Baytown, TX 77520

Repair and Install Variable Frequency Drive on Irrigation Well 8
Results
Bushland, TX 79012

Water Well No. 2
Post-Bid
TX

Saws Water Well Mitigation Program
Results
Less than $97,000 est. value
San Antonio, TX

Granger Pines WWTP Site Work and Wet Well
Post-Bid
Conroe, TX 77301

Well Construction and Plugging of Existing Wells at the Fuller and Far North Well Sites
Results
TX

Well No. 2 Replacement
Post-Bid
Anthony, TX

Water Well Facilities for Pinewood Trails
Results
Less than $2,389,444 est. value
Cleveland, TX 77327

IFB Turbo Pump
Post-Bid
College Station, TX 77845

Plant 1 Improvements Contract 1 Water Wells #6 and #7
Results
$650,000 est. value
Tyler, TX 75706

Rockwall Heath High School Well Repair
Post-Bid
Heath, TX 75032

Reported 01/24/2020 12:00 AM
Project Title

High Service Pump Repair

Physical Address View project details and contacts
City, State (County) Athens, TX 75751   (Henderson County)
Category(s) Sewer and Water
Sub-Category(s) Pumps and Wells
Contracting Method Competitive Bids.
Project Status Request for Quotations
Bids Due View project details and contacts
Estimated Value
Plans Available from Municipal Agency
Owner View project details and contacts
Architect View project details and contacts
Description

Repair a horizontal, split case pump, designated HSP-4. The pump is an Allis Chalmers, Model 150, 8 X 6 X 17L, located at the Athens Municipal Water Authority Water Treatment Plant located at 5200 FM 2495, Athens TX, 75751.The selected Contractor shall be responsible for the on-site removal of the pump, performing the required maintenance off site, then return the pump items and reassembling the unit. The repair work shall include, but may not be limited to, the following items: 1) Initial on-site inspection of the pump, tear down, and removal of all or portions of the pump needed for rehabilitation. 2) Removal and replacement of shaft sleeve to accommodate specified mechanical seal. a) Provide cost as alternate to fabricate or purchase new 416 stainless steel shaft to replace the existing. 3) Clean and inspect existing stuffing and box and machine as needed to accept new seals, or provide pump specific stuffing box intended for mechanical seal. 4) Remove existing air release valve from the upper volute case and replace with threaded plug. 5) Replace bearings, O-rings, and gaskets. 6) Inspect and replace rotating and stationary wear rings if needed. 7) Trim existing impeller as instructed by City of Athens. a) Existing diameter of 17” may be reduced to 15” to match head curve of other pumps at this location. 8) Dynamic balance of rotating element. 9) Reassemble and align pump and motor. 10) Pressure test pump to ensure operation at duty point. 11) Clean exterior surface to remove all grease/oil.

Details

Division 02 - Existing Conditions, Subsurface Investigation.
Division 03 - Concrete, Cast-in-Place Concrete.
Division 22 - Plumbing, Plumbing Piping, Plumbing Equipment.
Division 26 - Electrical, Instrumentation and Control for Electrical Systems.
Division 33 - Utilities, Water Utilities, Water Utility Distribution Piping, Water Utility Distribution Equipment, Water Utility Pumping Stations, Wells.
Division 44 - Pollution and Waste Control Equipment, Water Pollution Control Equipment.

Bidder's List View project details and contacts
Prospective Bidders View project details and contacts
Project Documents
 Engineered Spec Sheet
 Architectural Plans
 Other Documents