Similar Projects
Planned Service Agreement for York Chillers
Term Contract
Design
Stoneville, MS 38776

Replace Building Automation System Controls & Fan Coil Units
Term Contract
Design
Mississippi State, MS 39762

Middle School HVAC Improvements
Alteration
Bidding
Newton, MS 39345

Elementary Schools HVAC Replacements
Alteration
Bidding
Eupora, MS

THS PAC Chiller
Post-Bid
Tupelo, MS 38804

HVAC Improvements
Post-Bid
Jackson, MS

HVAC Control System
Results
MS

2020 HVAC & Electrical Upgrades
Results
$1,500,000 est. value
Tupelo, MS

Greaves Hall HVAC Success Renovations
Alteration
Bidding
Raymond, MS 39154

HVAC Service Provider
Term Contract
Post-Bid
Ellisville, MS 39437

HVAC Maintenance at City of Brookhaven Owned Facilities
Results
Brookhaven, MS

Marshall Hall HVAC Success Renovations
Alteration
Bidding
Raymond, MS 39154

Chiller Replacement
Term Contract
Post-Bid
Ellisville, MS

Renovation of 37,000 SF Industrial Building - Contract No. 2 - HVAC Unit Replacement
Results
Tylertown, MS

Hattiesburg High School RTU Replacement
Alteration
Bidding
Hattiesburg, MS 39401

Reported 02/11/2022 12:00 AM
Project Title

Replacement of HVAC for Chickasaw County Courthouse

Physical Address View project details and contacts
City, State (County) Houston, MS 38851   (Chickasaw County)
Category(s) Single Trades
Sub-Category(s) HVAC
Contracting Method Design-Build. Competitive Bids.
Project Status Bidding
Bids Due View project details and contacts
Estimated Value
Plans Available from Municipal Agency
Owner View project details and contacts
Architect View project details and contacts
Description

Complete replacement of heating, air conditioning, and ventilation system for Chickasaw County Courthouse, Houston, MS (National Historical Register Building) with one of the following system types: Option #1: Chilled/Hot Water System: Replacement of chiller, boiler, pumps, air handling units, fan coil units, piping, insulation, and controls. Provide improved ventilation/filtration. Removal/replacement of existing ceiling. Provide alternate for replacement of existing fluorescent lights with LED lights.Option #2: Variable Refrigerant Flow (VRF). Provide VRF system to replace existing chilled/hot water system. Provide improved ventilation/filtration. Removal/replacement of existing ceiling. Provide alternate for replacement of existing fluorescent lights with LED lights. Option #3: Water Source Heat Pump (WSHP). Provide WSHP system to replace existing chilled/hot water system. Provide improved ventilation/filtration. Removal/replacement of existing ceiling. Provide alternate for replacement of existing fluorescent lights with LED lights.

Details

Division 23 - Heating, Ventilating, and Air Conditioning (HVAC), Instrumentation and Control for HVAC, HVAC Air Distribution, Central HVAC Equipment.

Bidder's List View project details and contacts
Prospective Bidders View project details and contacts
Project Documents
 Engineered Spec Sheet
 Architectural Plans
 Other Documents