Similar Projects
Citywide Generator Maintenance and Emergency Repair Services
Alteration
Bidding
Atlanta, GA

Alternate Aviation Ground Power Unit (AGPU) Generator
Post-Bid
Atlanta, GA

Annual Contract for Electrical Testing and Inspection Services
Term Contract
Post-Bid
Atlanta, GA

Midtown Atlanta Regional Activity Center - Pedestrian Mobility
Results
Atlanta, GA 30303

Underground/Overhead Electrical Distribution and Emergencies Contract
Results
Less than $500,000 est. value
East Point, GA 30344

On-Call Electrical Services
Term Contract
Post-Bid
Alpharetta, Milton, Roswell, GA 30004

Electrical Contractor Services - Science Annex - Replace Building Switchgear System
Results
Less than $175,000 est. value
Atlanta, GA 30303

Hanger Fans
Term Contract
Post-Bid

Sparks Hall - Replace Building Switchgear System
Results
Less than $365,000 est. value
Atlanta, GA 30303

Generator Upgrade for Atlanta DDS Facility
Alteration
Post-Bid
Atlanta, GA 30303

Airfield Electrical On-Call Contract
Term Contract
Results
Atlanta, GA 30336

Electrical Repair Services
Alteration
Post-Bid
GA

Runway End Identifier Light Repair Service
Results
Atlanta, GA 30336

Generator System Maintenance and Repair Services
Alteration
Post-Bid
Atlanta, College Park, Conley, Ellenwood, Fayetteville, Forest Park, Hampton, Jonesboro, Morrow, Rex, Riverdale, GA 30236

Utility Services
Term Contract
Results
Atlanta, GA 30313

Reported 06/01/2022 12:00 AM
Project Title

175 Piedmont North A & B - Electrical Modifications

Physical Address View project details and contacts
City, State (County) Atlanta, GA 30303   (Fulton County)
Category(s) Single Trades
Sub-Category(s) Electric
Contracting Method Competitive Bids.
Project Status Accepting Qualifications
Bids Due View project details and contacts
Estimated Value $750,000
Plans Available from State Agency - 04/29/22
Owner View project details and contacts
Architect View project details and contacts
Description

Possible coordination issue on existing 1200-amp Main Distribution Panel MDP1 main breaker at the 175 Piedmont Dorms Buildings A & B requiring a Short Circuit, Protective Device Coordination and Arc-Flash Study Contractor shall gather the field data necessary for the performance of the Study (e.g. determine existing conductor lengths, verification of existing conductor sizes, panel dead-front removal to obtain device AIC ratings) Contractor shall perform the Short Circuit Study, Equipment Evaluation and Arc Flash Study Contractor will apply the arc-flash warning labels in the field Add a second emergency generator

Details

Division 26 - Electrical.

Bidder's List View project details and contacts
Prospective Bidders View project details and contacts
Project Documents
 Engineered Spec Sheet
 Architectural Plans
 Other Documents