Similar Projects
Last Updated | 03/25/2020 11:54 AM |
Project Title | Housing Rehabilitation - Pocomoke City |
Physical Address | View project details and contacts |
City, State (County) | Pocomoke City, MD 21851 (Worcester County) |
Category(s) | Residential |
Sub-Category(s) | Single-Family Homes |
Contracting Method | Competitive Bids. |
Project Status | Results |
Bids Due | View project details and contacts |
Estimated Value | |
Plans Available from | |
Owner | View project details and contacts |
Architect | View project details and contacts |
Description | Remove all existing roof shingles, underlayment, flashings, and drip edge. Remove existing gutters and downspouts. Replace any water damaged roof sheathing. Provide and install minimum thirty pound felt paper underlayment. Provide and install new wide white aluminum drip edge. Install ice and water shield at all eaves, rakes, as well as all roof valleys and wall/roof junctions. Provide and install thirty year architectural shingles per manufacturer's installation instructions. Provide and install roof ridge venting with hip and ridge caps as necessary. Provide and install new plumbing vent boots as required. Install aluminum step flashings at chimney. Install new white continuous gutters and downspouts with splash blocks at each downspout. Remove crawlspace door and install new insulated metal access door. Remove all crawlspace insulation and vapor barrier. Install new R-19 Kraft faced fiberglass batt insulation in all floor joists bays in the crawlspace. Install new 6 mil poly vapor barrier in the crawlspace. Vapor barrier to have a minikum 12 inch overlap at all seams and is to completely cover the crawlspace floor area. Install metal dryer duct from the dryer unit rear connection through the crawlspace and out the exterior wall, terminating in a self closing dryer vent hood. Dryer duct to be properly supported in the crawlspace. Install GFCI outlets in the bathroom, kitchen sink area, and at the exterior. Install a bathroom exhaust fan in the bathroom ceiling and vent it to the exterior per current Code. Install State mandated 10 year life, lithium battery smoke detectors in house, including all bedrooms per current Code. If hard wiring all units would require major demolition and repairs, single battery operated units will be acceptable in the bedroom currently not having hard wired units. Replace the sliding glass door panel glass that has a failed glazing seal. The new glass is to be safety glass, as well as Low-E, insulated glass. Repair entry steps that are loose and have failed mortar joints. |
||||||||||||||
Details | 1 Single-Family Homes, Renovation.
|
||||||||||||||
Bidder's List | View project details and contacts | ||||||||||||||
Prospective Bidders | View project details and contacts | ||||||||||||||
Project Documents |
Engineered Spec Sheet Architectural Plans Other Documents |