Last Updated | 04/12/2023 10:04 AM |
Project Title | Rehabilitation of Four (4) Single Phase Main Transformers |
Physical Address | View project details and contacts |
City, State (County) | Byron, CA 94514 (Contra Costa County) |
Category(s) | Government/Public |
Sub-Category(s) | Misc. Buildings |
Contracting Method | Competitive Bids |
Project Status | Results, Construction start expected April 2023 |
Bids Due | View project details and contacts |
Estimated Value | $2,897,200 [brand] Estimate |
Plans Available from | Agency's Affiliate |
Owner | View project details and contacts |
Architect | View project details and contacts |
Description | **As of April 5,2023, this project has not yet been awarded. A timeline for award has not yet been established.** The San Luis & Delta-Mendota Water Authority is soliciting proposals for the rehabilitation of four (4) single phase main transformers. For any interested contractor, please respond via email to the Authority contact: Travis Roberts, Contract Specialist 209-832-6259 Travis.roberts@sldmwa.org Tracy The method of Contractor Selection has not been Determined at this time. Work is located at O'Neill Pumping-Generating Plant approximately 12 miles west of Los Banos, California, in Merced County, as shown on the Location Map, drawing 805- D-786. Schedule of Contract Milestones: 1. Spare Transformer Tank Lid Analysis Complete: minimum 21 calendar days before beginning Spare Transformer Rehab. 2. Spare Transformer Delivery of Materials: minimum 4 calendar days before beginning Spare Transformer Rehab. 3. Spare Transformer Rehabilitation Pre-Work Tests: minimum 21 calendar days before outage start date. 4. Spare Transformer Ready to Move Into Final Location: minimum 1 calendar day before outage start date. 5. In-Service Transformers Delivery of Materials: minimum 7 calendar days before outage start date. 6. Spare Transformer Commission Testing: within 10 calendar days after outage start date. 7. In-Service Transformers Pre-Work Tests: within 1 calendar day after outage start date. 8. In-Service Transformers Commission Testing: within 38 calendar days after outage start date. 9. Protective Relay Commission Testing: within 44 days after outage start. |
||||||||||||||||||||||||||||||||
Details |
|
||||||||||||||||||||||||||||||||
Bidder's List | View project details and contacts | ||||||||||||||||||||||||||||||||
Prospective Bidders | View project details and contacts | ||||||||||||||||||||||||||||||||
Project Documents |
Engineered Spec Sheet Architectural Plans Other Documents |