Similar Projects
Reported | 11/20/2020 12:00 AM |
Project Title | Office of Emergency Management Renovation and Fit-Out of Floors 8-10 |
Physical Address | View project details and contacts |
City, State (County) | Philadelphia, PA 19108 (Philadelphia County) |
Category(s) | Government/Public |
Sub-Category(s) | Misc. Buildings |
Contracting Method | Competitive Bids. |
Project Status | Request for Proposals (RFPs) |
Bids Due | View project details and contacts |
Estimated Value | |
Plans Available from | Architect |
Owner | View project details and contacts |
Architect | View project details and contacts |
Description | The Work covers the renovation/fit-out of floors 8, 9 and 10, plus related work on other floors, the site and the building exterior for the Office of Emergency Mnagement locted in the Philadelphia Public Services Building. THE FITOUT INCLUDES BUSINESS USE GROUP B AND ASSEMBLY GROUP A-3 SPACES. - INTERIOR RENOVATION INCLUDES NEW INTERIOR WALLS, DOORS AND FRAMES, CEILINGS, RESTROOMS, FINISHES AND SIGNAGE. - NEW MECHANICAL SYSTEMS WORK INCLUDES A NEW DOAS AND SMOKE PURGE SYSTEM WITH ENERGY RECOVERY. THE EXTERIOR DOAS EQUIPMENT WILL BE LOCATED ON THE 14TH FLOOR ROOF, WITH DUCT SYSTEMS PENETRATING FLOORS 13, 12 AND 11. - NEW AUTOMATIC FIRE SPRINKLER SYSTEM WILL BE INSTALLED AND WILL EXTEND THE BASE BUILDING SYSTEM. - NEW PLUMBING WORK INCLUDES ADDING RESTROOMS, SHOWERS, AND PANTRY AREAS. - NEW ELECTRICAL SYSTEMS WORK EXTENDS THE DISTRIBUTION SYSTEMS AND INCLUDES A BACKUP GENERATOR WITH HIGHVOLTAGE CONNECTION TO SERVE OEM. THE GENERATOR AND OIL TANK WILL BE LOCATED ON THE BASEMENT LEVEL NEAR 15TH STREET. - NEW LED LIGHTING WILL BE INSTALLED THROUGHOUT. - NEW DATA AND COMMUNICATIONS CONNECTIVITY EXTENDS TO THE 2ND AND 5TH FLOORS OF THE BASE BUILDING. - NEW OFFICE FURNITURE WILL BE INCLUDED IN THIS PROJECT, PROVIDED BY THE OWNER. - EXISTING BASE BUILDING SYSTEMS AND FACILITIES SERVING FLOORS 8, 9 AND 10 ARE NOT INCLUDED IN THE TENANT SCOPE OF WORK. THIS INCLUDES TOILET ROOMS, IDF AND ELECTRICAL ROOMS, PASSENGER ELEVATORS AND FIRE STAIRS, AND EXTERIOR WALLS AND GLAZING - THE PPSB IS A HISTORICALLY REGISTERED BUILDING. |
||||||||||||||||||||||||||||||||
Details | Misc. Buildings, 9,765 SF Build-Out.
|
||||||||||||||||||||||||||||||||
Bidder's List | View project details and contacts | ||||||||||||||||||||||||||||||||
Prospective Bidders | View project details and contacts | ||||||||||||||||||||||||||||||||
Project Documents |
Engineered Spec Sheet Architectural Plans Other Documents |