Similar Projects
Sabine Neches Waterway PA8 Containment Dike Raise
Design
$1,000,000 to $5,000,000 est. value
TX

Nueva Street Marina Fabridam Replacement
New Construction
Bidding
$435,000 est. value
San Antonio, TX 78275

Lake Dam Improvements
Renovation
Bidding
$7,800,000 to $8,100,000 est. value
Austin, TX 78744

Construction: Lewisville Spillway
Post-Bid
$25,000,000 to $100,000,000 est. value
Lewisville, TX

Lower Bois d'Arc Creek Reservoir Dam and Intake Project - Proposal Package 4A CR2700 Improvements
Post-Bid
$750,000 est. value
Honey Grove, TX 75446

Tom Miller Dam Replacement Chains
Results
Less than $175,000 est. value
Austin, TX

Dam Reconstruction at Bastrop State Park
Results
$7,500,000 to $8,300,000 est. value
Bastrop, TX 78602

Elm Creek (Cen-Tex) Watershed – Sites 37, 38 and 43 Repairs
Bidding
$500,000 to $750,000 est. value
Temple, TX

Lower Bois D`Arc Creek Reservoir Dam and Intake Project - Proposal Package 3 Reservoir Cleanup
Post-Bid
$750,000 est. value
Honey Grove, TX 75446

Lane City Dam Interim Stabilization
Results
Lane City, TX 77453

Sister Grove Regional Water Resource Recovery Facility Outfall Pipeline 1 - Solicitation Set 01 - Large Diameter Tunnel Work and Large Diameter Pipe Materials
Post-Bid
TX

Houston Ship Channel, Mid Bay Placement Area (PA) Improvements
Results
$5,000,000 to $10,000,000 est. value
TX 77571

LBCR Dam and Intake Project - Proposal Purchase Package 6B - Barrier and Warning System
Post-Bid
$350,000 est. value
Honey Grove, TX 75098

Houston Ship Channel, Texas, Clinton Placement Area Improvements in Harris County, Texas
Results
$5,000,000 to $10,000,000 est. value
Houston, TX 77002

Lake Ralph Hall: Leon Hurse Dam
Post-Bid
$135,000,000 to $165,000,000 est. value
TX

Reported 04/11/2020 12:00 AM
Project Title

Z2PZ--Rebuilding of Gate 4 Support Systems and Opener at Waco

Physical Address View project details and contacts
City, State (County) Waco, TX 76711   (McLennan County)
Category(s) Heavy and Highway
Sub-Category(s) Dam/Tunnel
Contracting Method Competitive Bids.
Project Status Request for Quotations
Bids Due View project details and contacts
Estimated Value
Plans Available from Federal Agency
Owner View project details and contacts
Architect View project details and contacts
Description

The contractor shall be responsible for providing all labor, materials, and equipment need for the services required to rebuild Gate 4 at the Waco VA Campus. Work performed will be done at the Central Texas Veterans Health Care Facility in Waco, at 4800 Memorial Drive, Waco, Texas 76504, on Gate 4. After all work is completed, the contractor will have a walkthrough with the VA COR and Operators to ensure all work is completed and ready to receive payment. The contractor shall provide all personnel, services, vehicles, transportation, tools, equipment, materials, supplies, facility supervision, administration supervision and any other item(s) necessary to perform and accomplish this service. The contractor shall be familiar with all the terms, conditions, and requirement herein contained. All work must comply with federal, state and local regulations. All work shall be done according to the Infection Control Risk Assessment (ICRA) specified for the respective areas where work is performed. Project Requirements Base Bid Demo Process Gate 4 Demo Process Demo Gate Opener System Disconnect and/or remove all power, openers, wiring, loops and etc. connected to Gate 4. Remove completely disconnect openers from the concrete pad. Openers will remain onsite. Must mark all control wires to Gate 4. Inspect openers and provide a list of parts need for repairs and updates to the VA Opener System. Demo Existing Track Demo existing concrete that holds the track system. Remove the track system from the concrete Remove any conduit stubbed into the concrete. Haul off all debris and trash per EPA removal process Remove Gate Panels Grinded all weld joints down for a smooth transition between joints. Remove existing rails and panels. Base Bid New Work Gate 4 Rebuild Remove Gate Panels Remount rails on gates using new U-Bolts facing in the correct directions. Install new channel iron on top of each gate panel to help guide gates through new rollers. Install weldable mounting boxes with 4 new 6 in. sealed bearing V-groove wheels. Install 4 new 6 in heavy duty guide rollers. Install New Support System Form and pour a new concrete pad fitted with an installed angle iron track for V-groove wheels. Route all conduits to stub up from the concrete pad within new base risers, this will improve the look of the gate, increase safety, and reduce tripping hazards while protecting surrounding openers Rebuild Gate Opening System Inspected all marked control wiring and replace if necessary. Inspect existing opener and repair. Install the following: 2 new radio receivers, 2 new 12 in. Hysecurity base risers, 4 monitored UL 325 reflective phone eyes with hoods. Install mounting posts for photo eyes and 2 seven-day timers. Make sure all connections are secured. Reinstall openers and reconnect all control wiring/control loop. Reconnect power and test opener system to ensure gate 4 is operable once again. At the end of the project clean up and haul off any debris, extra materials or waste that has accumulated during the project in accordance with EPA Guidelines and Regulations.

Details

Division 02 - Existing Conditions, Subsurface Investigation.
Division 31 - Earthwork, Site Clearing, Grading, Excavation and Fill, Subgrade Preparation, Excavation, Shoring, Tunneling and Mining, Tunnel Excavation.
Division 35 - Waterway and Marine Construction, Dam Construction and Equipment.

Bidder's List View project details and contacts
Prospective Bidders View project details and contacts
Project Documents
 Engineered Spec Sheet
 Architectural Plans
 Other Documents