Similar Projects
Last Updated | 01/30/2019 03:03 AM |
Project Title | Installation of an Intelligent Transportation System (29 Closed Circuit Television Cameras), 3 Variable Message Signs, 2 Road Weather Information Systems and 2 Traffic Counting Stations) Along Section |
Physical Address | View project details and contacts |
City, State (County) | State-Wide: MA |
Category(s) | Single Trades |
Sub-Category(s) | Security/Communications |
Contracting Method | Competitive Bids. |
Project Status | Results |
Bids Due | View project details and contacts |
Estimated Value | $5,413,962 |
Plans Available from | |
Owner | View project details and contacts |
Architect | View project details and contacts |
Description | Installation of an Intelligent Transportation System (29 Closed Circuit Television Cameras), 3 Variable Message Signs, 2 Road Weather Information Systems and 2 Traffic Counting Stations) along Sections of Interstates 93, 95, 495 and Routes 1, 1A and 128 "1.000","Ls","Schedule Of Operations - Fixed Price $42,000","100." "1.000","Ls","As-Built Survey And Plans","100.9" "160.000","Hr","Tree Trimming Crew - Tree And Stump Removal Crew","102.001" "340.000","Cy","Test Pit For Exploration","141.1" "25.000","Cy","Class b Rock Excavation","144." "30.000","Cy","Gravel Borrow","151." "40.000","Cy","Controlled Density Fill - Excavatable","153." "4.500","Ton","Crushed Stone","156." "859.000","Sy","Fine Grading And Compacting - Subgrade Area","170." "1050.000","Ft","Drive Sample Boring","191." "120.000","Ft","Hollow Stem Auger Borings","191.10" "40.000","Ft","Core Boring","191.11" "543.000","Ft","Horizontal Directional Drilling","191.311" "290.000","Lb","Calcium Chloride For Roadway Dust Control","440." "117.000","Ton","Contractor Quality Control","450.90" "117.000","Ton","Hma For Patching","451." "29.000","Gal","Asphalt Emulsion For Tack Coat","452." "1472.000","Ft","Hma Joint Sealant","453." "802.500","Ft","Guardrail, Tl-3 (Single Faced)","620.13" "8.000","Ea","Trailing Anchorage","627.1" "6.000","Ea","Guardrail Tangent End Treatment, Tl-3","627.83" "2.000","Ea","Transition To Nchrp 350 Guardrail","628.21" "2.000","Ea","Transition To Rigid Barrier (Single Faced)","628.22" "1.000","Ea","Transition To Thrie Beam","628.25" "650.000","Ft","Highway Guard Removed And Reset","630." "297.500","Ft","Highway Guard Removed And Discarded","630.2" "13.000","Ft","60 Inch Chain Link Fence (Spring Tension Wire) (Line Post Option)","644.060" "33.000","Ft","72 Inch Chain Link Fence (Spring Tension Wire) (Line Post Option)","644.072" "4.000","Ft","60 Inch Chain Link Gate With Gate Posts","650.060" "4.000","Ft","72 Inch Chain Link Gate With Gate Posts","650.072" "7.000","Ea","60 Inch Chain Link Fence End Post","652.060" "17.000","Ea","72 Inch Chain Link Fence End Post","652.072" "2.000","Ea","60 Inch Chain Link Fence Corner Or Intermediate Brace Post","653.060" "2.000","Ea","72 Inch Chain Link Fence Corner Or Intermediate Brace Post","653.072" "46.000","Ft","Chain Link Fence Removed And Discarded","665.01" "130.000","Ft","Chain Link Fence Removed And Reset","666." "23.000","Mo","Engineers Field Office And Equipment (Type a)","740." "1.000","Ls","Mobilization","748." "965.000","Ft","Compost Filter Tubes","767.12" "849.000","Ft","Pavement Milling Mulch Under Guard Rail","769." "280.000","Ft","Dual 1-1/2 Inch Communications Conduit Type Nm - Hdpe","804.152" "6740.000","Ft","3 Inch Electrical Conduit Type Nm - Plastic - (Ul)","804.31" "1020.000","Ft","1 Inch Electrical Conduit Type Rm - Galvanized Steel","806.1" "400.000","Ft","2 Inch Electrical Conduit Type Rm - Galvanized Steel","806.2" "400.000","Ft","3 Inch Electrical Conduit Type Rm - Galvanized Steel","806.3" "6.000","Ea","Electric Manhole - Sd2.010","811.10" "87.000","Ea","Electric Handhole - Sd2.023","811.23" "5.000","Ea","Communication Handhole - Sd2.023","811.231" "550.000","Ft","24 Strand Single Mode Fiber Optic Cable","813.251" "1.000","Ls","Power Service Connection ?93nb-Cctv-34.0","813.801" "1.000","Ls","Power Service Connection ?93nb-Cctv-39.2","813.802" "1.000","Ls","Power Service Connection ?93nb-Cctv-41.4","813.803" "1.000","Ls","Power Service Connection ?93sb-Cctv-42.4","813.804" "1.000","Ls","Power Service Connection ?93nb-Cctv-45.0","813.805" "1.000","Ls","Power Service Connection ?495sb-Cctv-114.8","813.806" "1.000","Ls","Power Service Connection ?495sb-Vms-93.0","813.807" "1.000","Ls","Power Service Connection ?495nb-Cctv-99.6","813.808" "1.000","Ls","Power Service Connection ?495nb-Cctv-100.0","813.809" "1.000","Ls","Power Service Connection ?495sb-Cctv-101.0","813.810" "1.000","Ls","Power Service Connection ?495nb-Cctv-101.4","813.811" "1.000","Ls","Power Service Connection ?495nb-Cctv-102.0","813.812" "1.000","Ls","Power Service Connection ?495sb-Cctv-104.4","813.813" "1.000","Ls","Power Service Connection ?128nb-Cctv-39.8","813.814" "1.000","Ls","Power Service Connection ?128sb-Cctv-40.4 & 128sb-Tcs-40.4","813.815" "1.000","Ls","Power Service Connection ?128nb-Cctv-41.2","813.816" "1.000","Ls","Power Service Connection ?128sb-Cctv-41.8","813.817" "1.000","Ls","Power Service Connection ?128sb-Cctv-43.4","813.818" "1.000","Ls","Power Service Connection ?128sb-Cctv-44.2","813.819" "1.000","Ls","Power Service Connection ?128sb-Vms-43.0 & 128sb-Tcs-43.0","813.820" "1.000","Ls","Power Service Connection ?95sb-Cctv-89.8","813.821" "1.000","Ls","Power Service Connection ?95sb-Vms-90.8","813.822" "1.000","Ls","Power Service Connection ?95nb-Cctv-88.0","813.823" "1.000","Ls","Power Service Connection ?95sb-Cctv-74.2 & 95-Rwis-74.2","813.824" "1.000","Ls","Power Service Connection ?95sb-Cctv-72.4","813.825" "1.000","Ls","Power Service Connection ?95nb-Cctv-50.4","813.826" "1.000","Ls","Power Service Connection ?1sb-Cctv-52.4","813.827" "1.000","Ls","Power Service Connection ?1me-Cctv-55.0 & 1me-Rwis-55.0","813.828" "1.000","Ls","Power Service Connection ?1sb-Cctv-54.0","813.829" "1.000","Ls","Power Service Connection ?1anb-Cctv-51.6","813.830" "1.000","Ls","Power Service Connection ?1anb-Cctv-52.4","813.831" "1.000","Ls","Power Service Connection ?1anb-Cctv-52.6","813.832" "31.000","Ea","Signal Post And Base Standard - 8 Foot","817.10" "3.000","Ea","Camera Pole With Lowering Device And Foundation ? 40 Foot","817.544" "26.000","Ea","Camera Pole With Lowering Device And Foundation ? 60 Foot","817.546" "32.000","Ea","Ip Cctv Camera - Ptz Type","819.22" "32.000","Ea","Grounding, Transient Voltage Surge And Lightning Protection","819.231" "29.000","Ea","Camera Pole Mounted Cabinet","819.27" "2.000","Ea","Traffic Counting Station (Tcs)","819.61" "2.000","Ea","Fiber Optic Ethernet Switch","819.741" "30.000","Ea","4g Lte Cellular Modem","819.742" "2.000","Ea","4g Lte Cellular Modem For Tcs","819.743" "2.000","Ea","24 Position - Fiber Optic Patch Panel","819.744" "2.000","Ea","4g Lte Cellular Modem For Rwis","819.745" "32.000","Ea","Remote Power Manager","819.746" "1.000","Ls","Network And System Configuration","819.751" "1.000","Ls","Field Site And Integrated Systems Testing","819.752" "1.000","Ls","Its Equipment Training","819.753" "1.000","Ls","Operations And Maintenance","819.754" "1.000","Ls","Prototype Integration Testing","819.755" "2.000","Ea","Co-Located Road Weather Information System (Rwis)","819.910" "2.000","Ea","Highway Utility Pole - Wood","821.09" "3.000","Ea","Variable Message Sign (Vms), Controller And Pole Mounted Cabinet","824.611" "185.000","Sf","Overhead Guide Sign - Aluminum Panel (Type b)","828.1" "1.000","Ea","Overhead Guide Sign And/Or Support Removed And Discarded","828.31" "2.000","Ea","Overhead Guide Sign Removed And Relocated","828.32" "18.000","Ea","Delineation For Guard Rail Termini","833.7" "1.000","Ls","Supports For Overhead Vms 95sb-Vms-90.8","840.311" "1.000","Ls","Supports For Overhead Vms 495sb-Vms-93.0","840.312" "1.000","Ls","Supports For Overhead Vms 128sb-Vms-43.0","840.313" "1600.000","Hr","Roadway Flagger","850.41" "480.000","Day","Traffic Cones For Traffic Management","851.1" "4000.000","Sf","Safety Signing For Traffic Management","852." "12.000","Ea","Portable Breakaway Barricade Type Iii","853.1" "5000.000","Ft","Temporary Barrier Removed And Reset","853.21" "1500.000","Ft","Temporary Barrier (Tl-3)","853.23" "1920.000","Day","Truck Mounted Attenuator","853.403" "6.000","Ea","Temporary Impact Attenuator For Shoulder, Incapable Of Redirection, Removed And Reset","853.411" "2.000","Ea","Temporary Impact Attenuator Unidirectional, Non-Redirective (Tl-3)","853.53" "120.000","Day","Temporary Illumination For Work Zone","853.8" "1920.000","Day","Arrow Board","856." "1344.000","Day","Portable Changeable Message Sign","856.12" "96000.000","Day","Reflectorized Drum","859." "122.000","Ea","Traffic Sign Removed And Reset","874.2" "1.000","Ea","Roadside Guide Sign And/Or Support Removed And Discarded","874.204" "1.000","Ea","Roadside Guide Sign Removed And Relocated","874.205" "5.000","Cy","4000 Psi, 1.5 Inch, 565 Cement Concrete For Post Foundation","901.3" "45.000","Sy","Special Slope Paving Under Bridge Removed And Reset","987.02" | ||||
Details |
|
||||
Bidder's List | View project details and contacts | ||||
Prospective Bidders | View project details and contacts | ||||
Project Documents |
Engineered Spec Sheet Architectural Plans Other Documents |