Similar Projects
Research Center Electrical Modifications
Post-Bid
Hunter, AL

UPS Batteries
Post-Bid
Maxwell Afb, AL 36112

MA-Electrical Repair and Maintenance Products
Results

Z--VISN 7 Solar PV Service and Maintenance Contract (VA-19-00016340)
Results
Montgomery, Tuscaloosa, AL - Augusta, Dublin, GA - Columbia, SC 35233

DODEA Americas UPS Upgrade and Warranty Services
Post-Bid

MA- DYS Generator Repair and Maintenance
Term Contract
Results
Montgomery, AL 36117

Weatherization Assistance Program (WAP)
Post-Bid

MA-Electrical Repairs - Statewide
Results

General Contractor Electrical Services
Term Contract
Post-Bid
Montgomery, AL 36104

MA-Electrical Repairs Public Fishing Lakes
Results
Montgomery, AL 361302620

Lighting Improvements at the Capitol Complex
Post-Bid
$500,000 to $700,000 est. value
Montgomery, AL 36104

J-- 619-20-1-5243-0008 Emergency Generator PM & MAINTENANCE (VA-19-00054180)
Results
Montgomery, Tuskegee, AL 36109

MA-ALDOT Troy Area Electrical Services and Repairs
Term Contract
Post-Bid
Montgomery, AL 302620

Repair Electrical Distribution
Post-Bid
$1,000,000 to $5,000,000 est. value
Montgomery, AL 36108

J045--Variable Frequency Drive (VFD) Replacement
Post-Bid
Montgomery, AL 36109

Reported 08/30/2019 12:00 AM
Project Title

Emergency Power and Radiator Repairs and Modifications Gordon Persons Building

Physical Address View project details and contacts
City, State (County) Montgomery, AL   (Montgomery County)
Category(s) Single Trades
Sub-Category(s) Electric
Contracting Method Competitive Bids.
Project Status Bidding
Bids Due View project details and contacts
Estimated Value
Plans Available from State Agency
Owner View project details and contacts
Architect View project details and contacts
Description Project Scope of Work to include following: 1. Providing all labor, equipment and materials as required for replacing existing roof mounted radiator with a new unit mounted on the First Floor Level in the ALPCO transformer vault yard for the Gordon Persons Building located at 50 North Ripley Street Montgomery, Alabama and in accordance with Contract Documents dated July 26, 2019. The Gordon Persons Building is considered a Business Occupancy. 2. Base Bid will: A. Abandon the existing roof mounted radiator, support structure and exposed piping on roof complete. Drain the existing piping and cap at First Floor ceiling level and label "NOT IN USE". Existing piping on First Floor level shall be removed complete. Existing piping run in 2-hour rated chase to be abandoned in place. B. Install equipment on new concrete pad(s) poured flush with existing ALPCO vault curbs. C. Install new 42" galavanized metal handrail at areaway in ALPCO transformer vault yard. D. Provide a 800kW, 277/480V 3PH 4W temporary generator to serve the building emergency power distribution system while the permanent generator is down for radiator modifications. 3. Bid Alternate No. 1: Install a new 1200A, 277/480V triple switch docking station in the ALPCO transformer vault yard on new concrete pad and associated feeders (4 parallel runs each 4 #350MCM and 1 #3/0 GND., 3"C.) from existing generator and from existing panel ED4 to docking station. 4. Bid Alternate No. 2: In place of Bid Alternate No. 1, Install a new 1200A, 277/480V triple switch docking station in the ALPCO transformer vault yard on new concrete pad and associated feeders (1200A, 480V, 3-Phase, 4-Wire with ground NEMA 3R copper bus duct). Bus duct shall terminate into docking station with no tap box. A tap box shall be permitted where required indoors. 5. Bid Alternate No. 3: In place of Bid Alternates No. 1 and 2, Install a new 1600A, 277/480V triple switch docking station in the ALPCO transformer vault yard on new concrete pad and associated feeders (5 parallel runs each 4 #400MCM and 1 #4/0 GND., 3"C.) from existing generator and from existing panel ED4 to docking station. 6. Bid Alternate No. 4: In place of Bid Alternates No. 1, 2, and 3, Install a new 1600A, 277/480V triple switch docking station in the ALPCO transformer vault yard on new concrete pad and associated feeders (1600A, 480V, 3-Phase, 4-Wire with ground NEMA 3R copper bus duct). Bus duct shall terminate into docking station with no tap box. A tap box shall be permitted where required indoors. 7. Bid Alternate No. 5: Remove existing remote radiator, associated structure and piping off roof and discard appropriately. Remove structure and cap piping just above roof level.
Details
Division 26 - Electrical.
Bidder's List View project details and contacts
Prospective Bidders View project details and contacts
Project Documents
 Engineered Spec Sheet
 Architectural Plans
 Other Documents