Similar Projects
Structure and Bridge
Term Contract
Post-Bid
Less than $5,000,000 est. value

Construction Management and Inspection Services for DC Plug Feeder Construction Projects
Term Contract
Post-Bid
Washington, DC

Preventative Maintenance at the Pentagon Heating and Refrigeration Plant
Results
Washington, DC 20301

C--Bridge Inspection and Assessment Worldwide
Results
$10,000 to $10,000,000 est. value

Multifamily Housing (MFH) Construction Inspection Services Contract
Post-Bid

Roof Fall Protection Services, Pentagon
Results
Arlington, VA

506 & 514 - Construction Management - Basic Ordering Agreement (B)
Term Contract
Post-Bid
$6,000,000 to $16,000,000 est. value
Washington, DC

Arboretum Assessment for Capitol Grounds and Arboretum
Results
Washington, DC

Inspection Of Cranes And Hoists
Post-Bid
Washington, DC

Two Ton Support Stands
Results
Washington, DC 20001

J042--Perform Repairs, Inspections & Testing on Fire and Smoke Barrier Doors
Post-Bid
Washington, DC - Baltimore, MD 21201

Construction Inspection Services
Results

L036--Elevator Inspection PM
Term Contract
Post-Bid
Washington, DC 20310

Field Utility Inspections
Term Contract
Results

Pressure Vessel Inspection and Hydrostatic Testing
Term Contract
Post-Bid

Last Updated 12/09/2021 04:19 PM
Project Title

Monthly Generator Service

Physical Address View project details and contacts
City, State (County) Washington, DC - Arlington, VA 22202   (District of Columbia (DC) - Arlington (VA) County)
Category(s) Professional Services
Sub-Category(s) Inspection Services
Contracting Method Competitive Bids.
Project Status Results
Bids Due View project details and contacts
Estimated Value
Plans Available from
Owner View project details and contacts
Architect View project details and contacts
Description

The contractor shall provide the tools, a Kohler factory trained technician, and equipment for the cleaning, inspecting, and the maintenance for 1 tank mounted generator. This unit is located at an airport which requires an escort on and off the facility. The technician that is providing the work will hold a valid government issued ID in order to be allowed on the government installation. Contractor shall provide written documentation for every visit outlining the preformed work. The contractor shall provide the following service as described below. Monthly 1. Visual check unit for leaks. 2. Wipe unit down. 3. Check fluid levels. 4. Check unit start time (5 sec. too full speed.) 5. Check battery cables for corrosion. 6. Check battery clamps and hold down clamps for tightness. 7. Check to ensure engine block heater is working correctly. 8. Visually ensure display functions properly. Annually 1. Change all filters, (oil, fuel and air). 2. Change oil following manufactures requirements. 3. Fuel and coolant testing. Send samples to an independent lab for analysis. Provide the report to the QAE via email directly from lab. 4. Fuel will be testing: D482,D524,D976,D2500,D130,D1298,D86,D93,D1796/D2709,D4294/D5453,D445 and Micro Organisms(yes or no). 5. Coolant will test for the following: Freeze point, PH, nitrate, Glycol% / antifreeze%, metal analysis, boil point, SCA# and total hardness. 6. Load test unit to 100% for 6hrs.

Details

Division 01 - General Requirements, Quality Control, Testing and Inspecting Services.
Division 26 - Electrical.