Similar Projects
Police Station Rooftop HVAC Upgrades
Alteration
Bidding
Fairfield, CT 06824

Rooftop HV Unit Replacement - FWHS Cafeteria Area (New) HVAC Unit
Alteration
Bidding
Fairfield, CT 06825

On Call HVAC Services
Term Contract
Post-Bid
Trumbull, CT 06611

HVAC Renovation Project
Post-Bid
Danbury, CT 06812

Supply and Installation of Rooftop Air Conditioning System at Middle Gate School
Results
Newtown, CT

Kitchen Hood Cleaning Services
Term Contract
Results
Stamford, CT

HVAC and Mechanical Products
Term Contract
Post-Bid

Silvermine Elementary School - Air Conditioning and Electrical Upgrades Project
Results
Less than $350,000 est. value
Norwalk, CT 06850

045--Chilled Water Line Repair
Post-Bid
West Haven, CT 06516

Town Hall Make-Up Air Unit Replacement
Results
Greenwich, CT 06830

K.T. Murphy School Toilet Exhaust Project for Stamford Public Schools
Post-Bid
Stamford, CT 06902

HVAC Preventive Maintenance Fairfield Public Schools
Results
Fairfield, CT 06824

Cabinet Unit Ventilator Inspection Repair and Maintenance for Stamford Public Schools
Alteration
Post-Bid
Stamford, CT 06902

Parks and Recreation Rooftop Unit (RTU) Replacement
Results
Ridgefield, CT 06877

AHU-A1 Roof Top Unit Repairs for Stamford Public Schools
Alteration
Post-Bid
Stamford, CT 06902

Last Updated 01/03/2022 04:45 PM
Project Title

Replacement of Two Rooftop Air Conditioning and Ventilation Units at Bethel High

Physical Address View project details and contacts
City, State (County) Bethel, CT   (Fairfield County)
Category(s) Single Trades
Sub-Category(s) HVAC
Contracting Method Competitive Bids.
Project Status Results
Bids Due View project details and contacts
Estimated Value
Plans Available from Municipal Agency
Owner View project details and contacts
Architect View project details and contacts
Description

The two (2) subject rooftop units are beyond their normal service life and require replacement. Information on the units follows. Also, see accompanying table for further details. AHU-9 is a Trane rooftop unit that provides air conditioning and ventilation to the school’s cafeteria. The RTU has a 15 hp supply fan and 40-ton DX coil and associated air-cooled condensing module with three compressors. AHU-13 is a Trane rooftop unit that provides air conditioning and ventilation to the school’s approximately 800-seat auditorium. The RTU has a 25 hp supply fan, 5 hp powered exhaust fan and 75-ton DX coil and associated air-cooled condensing module with two compressors.

Details

Division 23 - Heating, Ventilating, and Air Conditioning (HVAC), Instrumentation and Control for HVAC, HVAC Air Distribution, Central HVAC Equipment.

Bidder's List View project details and contacts
Prospective Bidders View project details and contacts
Project Documents
 Engineered Spec Sheet
 Architectural Plans
 Other Documents