Similar Projects
Overhead Door Replacement, Jasper AEM
Bidding
$50,000 est. value
Jasper, TX 75951

Replacement of 3 Entry Doors
Bidding
Denton, TX 76209

Clear Creek ISD Package 3 Vestibule Upgrades Project
Post-Bid
Columbus, TX

Glass, Services, Break Repair, Replacement and Miscellaneous Glass
Term Contract
Post-Bid
Pittsburg, TX 75686

Fire Escape Doors and Weld on Hinges - FY19
Results
Texarkana, TX 75501

Overhead Door-Service
Results
Fort Hood, TX

Overhead Door and Gate Maintenance and Repair for TXDOT Abilene District
Bidding
Abilene, Albany, Aspermont, Baird, Big Spring, Colorado City, Haskell, Jayton, Roby, Snyder, Sweetwater, TX 79601

Steel Doors for the Water Treatment Plant
Post-Bid
Athens, TX 75751

Door Replacement
Results
Irving, TX 75060

Door Repair Projects
Bidding
Dallas, TX

Fire Station Apparatus Bay Doors Replacement
Post-Bid
Addison, TX 75001

Door Access Control Updates
Results
TX 75002

Repairs to Handicap Door
Post-Bid
Houston, TX 77019

Glass Replacement Service
Term Contract
Results
Mesquite, TX 75150

Villa Sandoval-Longoria Window Replacement 2019
Post-Bid
Weslaco, TX

Last Updated 04/09/2021 10:06 AM
Project Title

Fire Door Inspections and Related Items

Physical Address View project details and contacts
City, State (County) Houston, TX   (Harris County)
Category(s) Single Trades
Sub-Category(s) Windows/Doors
Contracting Method Competitive Bids.
Project Status Results
Bids Due View project details and contacts
Estimated Value $100,000
Plans Available from
Owner View project details and contacts
Architect View project details and contacts
Description

Fire Door Inspections and Related Items for the Harris County Hospital District dba Harris Health System. Inspect fire-rated doors in accordance with National Fire Protections Association (NFPA) 80, Standard for Fire Doors and Other Opening Protectives, 2010 Edition, sections 5.2.4.1 and 5.2.4.2 a. Include all 11 items from 5.4.2.2: i. No open holes or breaks exist in the surface of either the door or frame. ii. Glazing, vision light frames, and glazing beads are intact and securely fastened in place, if so equipped. iii. The door, frame, hinges, hardware, and noncombustible threshold are secured, aligned, and in working order with no visible signs of damage. iv. No parts are missing or broken. v. Door clearances do not exceed clearances listed in 4.8.4 and 6.3.1.7. vi. The self-closing device is operational; that is, the active door completely closes when operated from the fully open position. vii. If a coordinator is installed, the inactive leaf closes before the active leaf. viii. Latching hardware operates and secures the door when it is in the closed position. ix. Auxiliary hardware items that interfere or prohibit operation are not installed on the door or frame. x. No field modifications to the door assembly have been performed that void the label. xi. Meeting-edge protection, gasketing, and edge seals, where required, are inspected to verify their presence and integrity.

Details

Division 08 - Openings, Doors and Frames, Windows.

Bidder's List View project details and contacts
Prospective Bidders View project details and contacts
Project Documents
 Engineered Spec Sheet
 Architectural Plans
 Other Documents