Similar Projects
Modify Atrium Lighting & Sprinklers - Mann Library
Conception
Ithaca, NY 14853

Inspection, Maintenance and Repair of Fire Alarm Systems at Various Agency Facilities
Term Contract
Bidding

Inspection, Maintenance and Repair of Fire Alarm Systems at Various Agency Facilities
Term Contract
Bidding

Fire Suppression Sprinkler System Maintenance
Post-Bid
Balmville, NY 125505075

Fire Alarm Systems Inspection
Term Contract
Post-Bid
Potsdam, NY 13676

Campus Center AC-2 Upgrade
Results
Albany, NY

N--Sara Alarm System Install
Results
$25,000 to $500,000 est. value
Stillwater, NY

Africana Studies And Research Center Fire Escape Repairs
Renovation - 88 SF
Construction
$49,600 est. value
Ithaca, NY 14850

Inspection, Testing, Maintenance, Repairs, and Central Station Monitoring of the Fire Alarm and Suppression Systems at Port Authority Bus Terminal
Term Contract
Post-Bid
New York, NY 10018

SUNY Purchase Commons Building S and Commons Building M Sprinkler Rehabilitation
Term Contract
Results
$800,000 to $900,000 est. value
Purchase, NY 10577

Fire Alarm Replacement at Various County Buildings
Post-Bid
Ithaca, NY 14850

Installation of NOVEC Fire & Smothering System
Results
$100,000 to $250,000 est. value
Dresden, NY 14441

Inspection, Maintenance and Repair of Fire Suppression
Post-Bid
NY

Gerry Hall Fire Alarm Replacement at SUNY Delhi
Results
$250,000 to $300,000 est. value
Delhi, NY 13753

Fire Alarm and Monitoring
Term Contract
Post-Bid
Astoria, NY 11105

Reported 04/14/2021 12:00 AM
Project Title

Horse Arena No. 50 Sprinkler Rehabilitation at SUNY Morrisville

Physical Address View project details and contacts
City, State (County) Morrisville, NY 13408   (Madison County)
Category(s) Single Trades
Sub-Category(s) Fire Protection
Contracting Method Competitive Bids.
Project Status Bidding
Bids Due View project details and contacts
Estimated Value
Plans Available from Copy Center
Owner View project details and contacts
Architect View project details and contacts
Description

The main features of work shall include, but not be limited to the following: Remove and replace existing dry-pipe sprinkler system in its entirety with a dry-pipe sprinkler system utilizing schedule 40 galvanized piping as indicated on the contract documents. Remove and replace existing electric driven fire pump, fire pump controller and associated equipment as indicated on contract documents. Provide new electrical feeders for new electric driven fire pump and associated fire alarm connections as indicated on the contract documents. Remove and replace existing sump pump located in fire pump room, and connect to existing underground drain piping as indicated on the contract documents.

Details

Division 21 - Fire Suppression.
Division 28 - Electronic Safety and Security, Fire Detection and Alarm.

Bidder's List View project details and contacts
Prospective Bidders View project details and contacts
Project Documents
 Engineered Spec Sheet
 Architectural Plans
 Other Documents