Similar Projects
Fire Alarm System
Bidding
Clover, SC 29710

Fire Extinguisher Services
Bidding
Beaufort, SC

Kitchen Hood and Fire Suppression System Inspections
Post-Bid
Summerville, SC 29483

Fire Panel Installation and Monitoring at 9 locations
Post-Bid
Aiken, SC

St Stephen's Fire Protection
Results
Alvin, SC 29479

Fire Sprinkler System at Congaree-Wood Early Childhood Center
Results
Less than $703,214 est. value
West Columbia, SC

Mullins High School Fire Alarm Upgrade
Bidding
Mullins, SC 29574

Fire Alarm Replacement Panel and Devices
Term Contract
Post-Bid
Greenville, SC 29611

EST-2 Network Fire Alarm System Replacement
Results
Charleston, SC 29412

Sumter Career and Technology Center Fire Alarm System Replacement
Bidding
Sumter, SC 29154

Veterans Victory House Fire Pump Control Replacement
Post-Bid
$130,000 to $160,000 est. value
Walterboro, SC 29488

MJPCH Fire Alarm Panel Replacement
Results
$25,000 to $100,000 est. value
Columbia, SC 29201

Fire Alarm System Replacement
Bidding
Sumter, SC 29154

Annual Fire Sprinkler Testing
Term Contract
Post-Bid
Orangeburg, SC

Fire Extinguisher Services
Term Contract
Results
Less than $6,420 est. value
Abbeville, Aiken, Anderson, Bamberg, Barnwell, Batesburg, Beaufort, Belton, Bennettsville, Bishopville, Bluffton, Camden, Chester, Chesterfield, Conway, Dillon, Edgefield, Fairfax, Florence, Fountain Inn, Gaffney, Georgetown, Greenville, Greenwood, Greer, Hartsville, Irmo, Kingstree, Ladson, Lake City, Lancaster, Laurens, Lexington, Manning, McCormick, Moncks Corner, Mullins, Myrtle Beach, Neeses, Newberry, North Augusta, North Charleston, Orangeburg, Pickens, Ridgeland, Rock Hill, Varnville, SC

Last Updated 01/25/2021 07:39 AM
Project Title

Expression of Interest to Design and Engineer Halon Fire Suppression Systems with FK-5-1-12 Clean Agent Fire Suppression Systems at the Savannah River Site- Located near Aiken, SC

Physical Address View project details and contacts
City, State (County) Aiken, SC   (Aiken County)
Category(s) Single Trades
Sub-Category(s) Fire Protection
Contracting Method Competitive Bids.
Project Status Results
Bids Due View project details and contacts
Estimated Value
Plans Available from
Owner View project details and contacts
Architect View project details and contacts
Description

Summary: Establish a Blanket Order Agreement (BOA) under which Task Orders will be issued to define, request and authorize specific tasks. Provide engineering and design services required for the replacement of existing Halon 1301 Fire Suppression Systems with FK-5-1-12 Clean Agent Fire Suppression System(s) in designated Liquid Waste Organization (LWO) buildings / facilities at the Savannah River Site (SRS). This Statement of Work (SOW) will establish a Blanket Order Agreement (BOA) under which Task Orders will be issued to define, request and authorize specific tasks. The fire suppression system replacement in each building or facility will be a separate Task Order. Required Codes / Standards National Fire Protection Association (NFPA) NFPA 2001, Standard on Clean Agent Fire Extinguishing Systems, 2018 Edition Underwriters Laboratories Inc. (UL) ANSI/UL 2166, Standard for Halocarbon Clean Agent Extinguishing System Units, 2012 Drawing/Sketches shall be supplied for a designated facility with each Task Order to enable Supplier/Subcontractor design. General LWO currently has seven (7) buildings / facilities with Halon fire suppression systems. These Halon systems are to be replaced with FK-5-1-12 systems. The scope covered under this subcontract shall be released incrementally by LWO Task Orders that are individually negotiated and include task specific technical and quality program requirements. The Subcontractor shall provide an FK-5-1-12 fire suppression system engineering and design package for a specific or designated building / facility at SRS that is identified in a detailed Task Order executed under the BOA. Each FK-5-1-12 fire suppression system shall be designed in accordance with NFPA 2001 requirements and shall be listed by Underwriters Laboratories Inc. or approved by FM Global. The technical and quality requirements provide a range of specific tasks expected to be executed. Each Task Order will clearly define all specific aspects of the task including, as appropriate: Engineering requirements Performance requirements Quality requirements Applicable codes & standards Schedule Deliverables Acceptance Method

Details

Division 21 - Fire Suppression.
Division 28 - Electronic Safety and Security, Fire Detection and Alarm.

Bidder's List View project details and contacts
Prospective Bidders View project details and contacts
Project Documents
 Engineered Spec Sheet
 Architectural Plans
 Other Documents