Similar Projects
Last Updated | 12/29/2022 05:04 PM |
Project Title | P-5001 Joint Air Defense Operations Phase 2 |
Physical Address | View project details and contacts |
City, State (County) | Washington, DC 20036 (District of Columbia County) |
Category(s) | Government/Public, Heavy and Highway, Sewer and Water |
Sub-Category(s) | Maintenance, Military Facility, Paving/Reconstruction, Sidewalks/Parking Lot, Site Development, Water Lines |
Contracting Method | Bids by Invitation, Competitive Bids |
Project Status | All Bids Received, Selection Expected, Construction start expected March 2023 |
Bids Due | View project details and contacts |
Estimated Value | $100,000,000 [brand] Estimate |
Plans Available from | Plan Holders |
Owner | View project details and contacts |
Architect | View project details and contacts |
Description | This acquisition will result in the completion of the Joint Air Defense Operations Center permanent facility by providing the second phase of the Military Construction: Construct a two-story Joint Air Defense Operations Center. Construction includes concrete slab-on-grade foundation with Concrete spread footings under steel columns, structural steel frame, concrete masonry unit shear walls, and roofing system with sloping roof deck. Includes pavements, all utilities, site improvements, passive force protection measures, security fencing, and diverse communication routing to eliminate single points of failure and ensure constant connectivity. Special Construction Requirements include Controlled Space in accordance with Intelligence Community Directive/Intelligence Community Standard 705 and use of special exterior finishes to meet Joint Base Anacostia Bollings architectural design requirements. The facility shall be compatible with applicable Department of Defense, Air Force, and Joint Base design standards. In addition, local materials and construction techniques shall be used where cost effective. Facilities will be designed as permanent construction in accordance with the Department of Defense Unified Facilities Criteria 1-200-01. This project will comply with Department of Defense antiterrorism/force protection requirements per Unified Facility Criteria 4-010-01. *The value for this project is based on a financial range. The value is listed as the highest possible cost from the range provided by a stakeholder or official project document. Addendum #1-#13 have been issued. |
||||||||||||||||||||||||||||||||||||||
Details | 2 Stories Above Grade, New Construction, New Construction.
|
||||||||||||||||||||||||||||||||||||||
Bidder's List | View project details and contacts | ||||||||||||||||||||||||||||||||||||||
Prospective Bidders | View project details and contacts | ||||||||||||||||||||||||||||||||||||||
Project Documents |
Engineered Spec Sheet Architectural Plans Other Documents |