Reported | 12/04/2020 03:38 PM |
Project Title | 56--CBRN Security Cage |
Physical Address | View project details and contacts |
City, State (County) | Savannah, GA 31409 (Chatham County) |
Category(s) | Single Trades |
Sub-Category(s) | Fencing |
Contracting Method | Competitive Bids. |
Project Status | All Bids Rejected |
Bids Due | View project details and contacts |
Estimated Value | |
Plans Available from | Federal Agency |
Owner | View project details and contacts |
Architect | View project details and contacts |
Description | The MICC End User requires the following items, Brand Name or Equal, to the following: LI 001: Metal Security Cage 40' W x 120' L x 12' H, 2148 square feet of metal cage must be anchored into concrete floor. Must have Wall Connections on Side 2 and Side 3. Must have Roof Metal Cage (40' X 120') #10 W&M Gauge (0.130 in.), bright basic wire welded into a 2” x 2” square mesh. Panels: Standard panel sizes are in one foot increments up to 5 feet by 10 feet in size. Horizontal and vertical frame members constructed from 1-1/4” x 1-1/4” x 1/8” hot rolled angle, with 1-1/4” x 3/8” slotted holes punched every 12 inches on center (O.C.). Vertical frame members are notched and welded to horizontal angle at corner seams. Wire mesh is securely welded to frame. Wire mesh position in angle frame may vary slightly.3.Panel stiffener bar: 1/4" x 3/4" thick hot rolled flat stock, center located and tack welded to wire mesh and horizontal frames on panels. Used only on 10-gauge wire mesh materials and panels greater than 5 feet long in any direction.4.Posts: 14-Gauge 2” x 2” square tube with a series of 7/16” diameter holes drilled on all four sides to accept hardware to connect panels and doors. Standard posts, ranging from 7’-2” to 12’-2” in one foot increments, are drilled with first hole at 8” above the finished floor and spaced every 12” O.C. leaving a 2” maintenance sweep space below the panels and doors. Tube is welded centered on a 2” x 7” x 1/4" steel flat base plate on standard posts. Base plate is punched to accept two 3/8” diameter anchors. Other base plate sizes are available upon request, or if quoted.5.Post extension inserts: 12-Gauge 1-3/4” x 1-3/4” square perforated tube, 18” long. Insert drops in to lower post and bolts to both lower and upper post sections.6.Growth plates: 12-Gauge 2” x 1-1/4” X 1-1/4” roll formed channel punched with 3/8” holes every 12” O.C. Growth plates bolt to panels, posts, and ceiling panels to offset 2” growth created by posts. Growth plates can also be specified to fill maintenance sweep space below panels and doors for higher security requirements. Wall Connections1-1/2” steel angle clips, punched to allow for anchoring to wall and attachment to posts using self-tapping screws. See Design, 1, EA; LI 002: 20' L x 11' H - Metal Cage Barn-Style Outward Opening Gate w/ Padlock On Side 2 See Design, 1, EA; LI 003: 4' W x 8' H - Metal Cage Outward Swinging Door w/ Padlock On Side 1 See Design, 1, EA; LI 004: shipping to 31409, 1, EA; LI 005: Installation, 1, EA; |
||||
Details |
|
||||
Bidder's List | View project details and contacts | ||||
Prospective Bidders | View project details and contacts | ||||
Project Documents |