Similar Projects
Emergency Cleaning, Remediation and Restoration Services
Post-Bid
Upper Marlboro, MD

Household Hazardous Waste Disposal
Term Contract
Post-Bid
Largo, MD

Lead Abatement Services for Two (2) Munitions Ranges Located within a U.S. Government Military Installation.
Results
Aberdeen Proving Ground, MD 21005

Coolant Pump Disposal
Results
Gaithersburg, MD

Hazardous and Universal Waste Disposal
Post-Bid
Washington, DC - Fort Meade, Hyattsville, Landover, MD - Culpeper, VA 20540

Comprehensive Multiple Component Waste Management Services Including Solid Waste and Refuse, Medical Pathological Waste, and Recycling
Results
Bethesda, MD 20892

Transportation, Storage and Composting of Sewage Sludge
Post-Bid
Frederick, MD 21702

J--RFI for Grease Trap Cleaning Height Restrictions Based on Access to Grease Traps Grease Traps Located on Lower Level in Garage
Results
Baltimore, MD 21201

Parkton Truck Scale House
Post-Bid
Less than $50,000 est. value
Parkton, MD

Bid Package 2A - Hazardous Material Abatement and Building Demolition for the Bay-Brook Elementary/Middle School
Results
Baltimore, MD

Industrial Hygiene Services for Multiple School Facilities
Term Contract
Post-Bid
MD

Petrochemical Removal, Disposal and Recycling Services
Results
Fort Detrick, MD

Environmental Decommissioning IDIQ
Post-Bid
Bethesda, MD 20892

Removal, Destruction and Disposal of Aqueous Film-Forming Foam (AFFF).
Results
Abbeville, AL

Animal Depopulation, Carcass Disposal, and Depopulation/ Euthanasia Technology
Post-Bid
Riverdale, MD 20737

Last Updated 01/07/2019 03:28 PM
Project Title

Maintenance and Calibration of Hazardous Waste Tank System

Physical Address View project details and contacts
City, State (County) Gunpowder, MD 21010   (Harford County)
Category(s) Environmental
Sub-Category(s) Hazardous Waste Disposal
Contracting Method Competitive Bids.
Project Status Results
Bids Due View project details and contacts
Estimated Value
Plans Available from Federal Agency
Owner View project details and contacts
Architect View project details and contacts
Description The Contractor shall provide on-call repair services, semi-annual preventative maintenance and calibration, and on-call troubleshooting services for its Hazardous Waste Tank System. The objective of this requirement is to provide Edgewood Chemical and Biological Center (ECBC) with regular and on-call maintenance services for the hazardous waste storage system at the Chemical Transfer Facility (CTF). The existing system contains the following: a. Sump tank Room 27-700 gallon capacity-Collects detoxified waste. Discharged to Neutralization system. b. Neutralization System. i. Two-1,450 gallon sodium hydroxide storage tanks. ii. One-500 gallon Sulfuric acid tank. iii. One-1,800 gallon receiving tank. iv. One-500 gallon reaction tank. v. Two-1,800 gallon final holding tanks. c. pH probes for each-sump tank, reactor tank, and both final hold tanks.
Details
Division 02 - Existing Conditions, Hazardous Material Assessment, Site Remediation, Contaminated Site Material Removal, Asbestos Remediation, Asbestos Abatement, Removal and Disposal of Asbestos Containing Materials.
Bidder's List View project details and contacts
Prospective Bidders View project details and contacts
Project Documents
 Engineered Spec Sheet
 Architectural Plans
 Other Documents