Similar Projects
HVAC, Electrical and Roofing On-Call Single Trade Services
Post-Bid
Denver, CO 80202

AFB 2141 CC 2018 Hail Damage Repairs
Post-Bid
$3,800,000 to $4,300,000 est. value
Colorado Springs, CO

AFICC Enterprise Wide Roofing Repair, Replacement, and Maintenance (R3M)
Results

AFICC Enterprise Wide Roofing Repair, Replacement, and Maintenance (R3M)
Results

Front Range Village
Renovation
Construction
Fort Collins, CO 80525

Heritage Park Restroom Renovation/Cleo Mudrock Baseball Dugout Roofing Project
Renovation
Construction
Less than $125,000 est. value
Louisville, CO 80027

City of Sterling Reroofing Project
Post-Bid
Sterling, CO 80751

Detention Center Roof G
Results
$100,000 to $150,000 est. value
Broomfield, CO 80021

Replace Roofs Main Building Southwest Campus Phases I and II Pueblo Community College
Construction
Less than $1,223,500 est. value
Mancos, CO 81328

Boulder Water Resource Recovery Facility Roofing Replacement Project
Post-Bid
Boulder, CO 80301

Safeway Roof Project
Results
Broomfield, CO 80020

Kit Carson Sand Shed Roof Repairs
Post-Bid
Kit Carson, CO 80825

Removal and Replacement Roofing
Results
Less than $60,000 est. value
Pueblo, CO 81001

Roof Replacement Johnson Building
Post-Bid
Rangely, CO

Tent Roof Maintenance and Repair
Results
Denver, CO

Reported 09/02/2020 12:00 AM
Project Title

Poncha Springs Roof and Wash Bay

Physical Address View project details and contacts
City, State (County) Poncha Springs, CO 81242   (Chaffee County)
Category(s) Single Trades
Sub-Category(s) Roofing
Contracting Method Competitive Bids.
Project Status Bidding
Bids Due View project details and contacts
Estimated Value $100,000
Plans Available from State Agency
Owner View project details and contacts
Architect View project details and contacts
Description

Qualified General Contractors are invited to bid on the replacement of a standing seam metal roof and conversion of two vehicle bays into a wash bay at an existing Vehicle Storage Facility (VSF) in Poncha Springs, CO. The existing building is a 140-foot by 50-foot 7,000 square foot pre-engineered metal building with a 3,000 square foot addition. The addition is not part of this project. The contractor shall remove the existing 7,000 sq. ft. metal roof and install a new insulated standing seam metal roof attached to the existing structure. As part of the roof replacement, the existing solotubes, radiant tube heaters and any other components that are attached to the roof structure shall be removed and reinstalled. The existing ceiling lights shall be demolished and replaced with new high-bay LED light fixtures. Additionally, two of the existing vehicle bays will be converted into a wash bay. The contractor shall upgrade the electrical components in those bays, provide and install a new pressure washer, provide FRP paneling on the wall, paint the existing metal, and install two hanging vinyl curtains.

Details

Division 07 - Thermal and Moisture Protection, Dampproofing and Waterproofing, Thermal Protection.

Bidder's List View project details and contacts
Prospective Bidders View project details and contacts
Project Documents
 Engineered Spec Sheet
 Architectural Plans
 Other Documents