Similar Projects
Building 11 Chiller Wall Repair
Alteration
Bidding
Charleston, WV 25305

Roane County Courthouse HVAC Maintenance
Alteration
Bidding
WV

Chiller and HVAC Full Service Comprehensive Contract - Joan C. Edwards School of Medicine
Post-Bid
Chapmanville, Huntington, WV

Chiller and HVAC Full Service Comprehensive Contract - Joan C. Edwards School of Medicine
Post-Bid
Chapmanville, Huntington, WV

Z--Eye Clinic HVAC Replacement Project Number 540-19-104
Results
$250,000 to $500,000 est. value
Bridgeport, WV 26330

HVAC Maintenance - Veterans Nursing Facility
Term Contract
Results
$30,239 est. value
Clarksburg, WV 26304

HVAC Renovations to the Princeton Senior High School
Alteration
Bidding
Princeton, WV 24740

Chiller Maintenance and Repair Services - Physical Plant Comprehensive Chiller Maintenance and Repair Services
Post-Bid
Huntington, WV 25755

TA Lowery Elementary School HVAC Replacement
Results
Shenandoah Junction, WV 25442

Smith Hall HVAC Renovation - Cooling Tower
Alteration
Bidding
Huntington, WV

Sorrell Maintenance Building HVAC System
Post-Bid
Huntington, WV 25755

PRT Central HVAC Replacement
Results
Morgantown, WV 26506

Installation of (36) Mini Split HVAC Systems
Alteration
Bidding
Williamson, WV

GCMAC - HVAC Equipment Maintenance Contract
Post-Bid
Moundsville, WV 26041

HVAC Installation
Results
$158,460 est. value
Benwood, WV 26031

Last Updated 10/27/2021 10:28 AM
Project Title

MCTEC Seminar Center HVAC

Physical Address View project details and contacts
City, State (County) Princeton, WV 24740   (Mercer County)
Category(s) Single Trades
Sub-Category(s) HVAC
Contracting Method Competitive Bids.
Project Status Results
Bids Due View project details and contacts
Estimated Value $19,158
Plans Available from
Owner View project details and contacts
Architect View project details and contacts
Description

Provide and install (2) two, 5-ton, 14 Seer split systems with 20 KW auxiliary heater packages. 2.2. Demo old systems and dispose of refrigerant, oils and other materials per EPA guidelines. 2.3. Remove acoustical ceiling in the space to allow removal of existing indoor air handlers and reinstall new ones. 2.4. Reinstall acoustical ceiling upon completion of installation of new units. 2.5. Reuse existing hangers for indoor air handlers and modify to hang new units. 2.6. Remove existing rooftop 5-ton heat pump condensers and set new systems on the same stands, modify if needed. 2.7. Vendor to provide crane/boom truck. The cost is to be included in vendor bid response. 2.8. Reconnect existing supply and return duct work and modify to reconnect to new systems. 2.9. Reconnect existing control to both the new units and modify if needed. 2.10. Reconnect all branch circuit wiring and breakers to all equipment, along with adding 2 new 250 volt 3-phase Nema 3-service disconnect. 2.11. Flush existing line sets with R-11 flush and reconnect to new equipment. Install new Armaflex and seal. 2.12. Leak test after connection and perform required manufactured evacuation.

Details

Division 23 - Heating, Ventilating, and Air Conditioning (HVAC), Instrumentation and Control for HVAC, HVAC Air Distribution, Central HVAC Equipment.

Bidder's List View project details and contacts
Prospective Bidders View project details and contacts
Project Documents
 Engineered Spec Sheet
 Architectural Plans
 Other Documents