Last Updated | 12/25/2019 11:36 PM |
Project Title | Installation of an Intelligent Transportation System (ITS) consisting of 19 Closed Circuit Television Cameras (CCTV), 3 Variable Message Signs (VMS), 3 Traffic Counting Stations (TCS) and 1 Continuous |
Physical Address | View project details and contacts |
City, State (County) | (Middlesex, Suffolk, Worcester Counties) |
Category(s) | Single Trades |
Sub-Category(s) | Security/Communications |
Contracting Method | Competitive Bids. |
Project Status | Results |
Bids Due | View project details and contacts |
Estimated Value | $3,421,000 |
Plans Available from | |
Owner | View project details and contacts |
Architect | View project details and contacts |
Description | 1.000","Ls","Schedule Of Operations - Fixed Price $32,500","100." "1.000","Ls","As-Built Survey And Plans","100.9" "104.000","Hr","Tree Trimming - Tree And Stump Removal Crew","102.001" "278.000","Cy","Test Pit For Exploration","141.1" "50.000","Cy","Class b Rock Excavation","144." "1.000","Ls","Environmental Health And Safety Program","180.01" "80.000","Hr","Personal Protection Level c Upgrade","180.02" "100.000","Hr","Licensed Site Professional Services","180.03" "33.000","Ton","Disposal Of Unregulated Soil","181.11" "66.000","Ton","Disposal Of Regulated Soil - In-State Facility","181.12" "50.000","Ton","Disposal Of Regulated Soil - Out-Of-State Facility","181.13" "17.000","Ton","Disposal Of Hazardous Waste","181.14" "464.000","Ft","Drive Sample Boring","191." "58.000","Ft","Hollow Stem Auger Borings","191.10" "58.000","Ft","Core Boring","191.11" "811.000","Ft","Horizontal Directional Drilling","191.311" "1525.000","Ft","Guardrail, Tl-3 (Single Faced)","620.13" "125.000","Ft","Guardrail, Tl-3 (Single Faced) In Concrete/Stone Apron","620.131" "8.000","Ea","Trailing Anchorage","627.1" "7.000","Ea","Guardrail Tangent End Treatment, Tl-3","627.83" "1.000","Ea","Transition To Nchrp 350 Guardrail","628.21" "4.000","Ft","60 Inch Chain Link Gate With Gate Posts","650.060" "4.000","Ft","72 Inch Chain Link Gate With Gate Posts","650.072" "80.000","Ft","Chain Link Fence Removed And Reset","666." "40.000","Ea","Silt Sack","697.1" "27.000","Mo","Engineers Field Office And Equipment (Type a)","740." "1.000","Ls","Mobilization","748." "2880.000","Ft","Sediment Control Barrier","767.121" "2035.000","Ft","Pavement Milling Mulch Under Guard Rail","769." "205.000","Ft","1.5 Inch Conduit Type Nm - Plastic -(Ul)","804.151" "4875.000","Ft","3 Inch Conduit Type Nm - Plastic -(Ul)","804.31" "220.000","Ft","1-1/2 Inch Electrical Conduit Type Rm - Galvanized Steel","806.15" "350.000","Ft","2 Inch Electrical Conduit Type Rm - Galvanized Steel","806.2" "50.000","Ft","3 Inch Electrical Conduit Type Rm - Galvanized Steel","806.3" "74.000","Ea","Electric Handhole - Sd2.023","811.23" "1.000","Ls","Power Service Connection – 24sb-Cctv-0.2","813.801" "1.000","Ls","Power Service Connection – 140sb-Cctv-18.6","813.802" "1.000","Ls","Power Service Connection – 195eb-Vms-36.9","813.803" "1.000","Ls","Power Service Connection – 195eb-Cctv-39.2 & 195wb-Cctv-39.2","813.804" "1.000","Ls","Power Service Connection – 495sb-Cctv-1.0","813.805" "1.000","Ls","Power Service Connection – 25eb-Vms-1.4 & 25eb-Cctv-1.4","813.806" "1.000","Ls","Power Service Connection – 25eb-Cctv-3.4","813.807" "1.000","Ls","Power Service Connection – 25wb-Vms-7.3","813.808" "1.000","Ls","Power Service Connection – 28me-Cctv-58.5, 28me-Cctv-58.7, & 28me- Ctds-58.4","813.809" "1.000","Ls","Power Service Connection – 28me-Cctv-61.4","813.810" "1.000","Ls","Power Service Connection – 6eb-Cctv-65.4","813.811" "1.000","Ls","Power Service Connection – 6wb-Cctv-65.4","813.812" "1.000","Ls","Power Service Connection – 6eb-Cctv-72.4","813.813" "1.000","Ls","Power Service Connection – 6wb-Cctv-72.4","813.814" "1.000","Ls","Power Service Connection – 6wb-Cctv-77.8","813.815" "1.000","Ls","Power Service Connection – 6eb-Cctv-84.4","813.816" "1.000","Ls","Power Service Connection – 6wb-Cctv-89.0","813.817" "27.000","Ea","Signal Post And Base Standard - 8 Foot","817.10" "1.000","Ls","Remove And Relocate Existing Camera Pole Equipment Site","817.540" "3.000","Ea","Camera Pole With Lowering Device And Foundation - 40 Foot","817.544" "13.000","Ea","Camera Pole With Lowering Device And Foundation - 60 Foot","817.546" "2.000","Ea","Tcs Pole And Foundation – 40 Foot","817.548" "18.000","Ea","Ip Cctv Camera - Ptz Type","819.22" "23.000","Ea","Grounding, Transient Voltage Surge And Lightning Protection","819.231" "16.000","Ea","Camera Pole Mounted Cabinet","819.27" "3.000","Ea","Traffic Counting Station (Tcs)","819.61" "19.000","Ea","4g Lte Cellular Modem And Antenna","819.741" "3.000","Ea","4g Lte Cellular Modem And Antenna For Tcs","819.742" "1.000","Ea","4g Lte Cellular Modem And Antenna For Ctds","819.743" "13.000","Ea","High Gain Cellular Antenna","819.744" "19.000","Ea","Remote Power Manager","819.745" "1.000","Ls","Network And System Configuration","819.751" "1.000","Ls","Field Site And Integrated Systems Testing","819.752" "1.000","Ls","Its Equipment Training","819.753" "1.000","Ls","Operations And Maintenance","819.754" "1.000","Ls","Prototype Integration Testing","819.755" "1.000","Ea","Four (4) Lane Continuous Traffic Data Station","819.904" "3.000","Ea","Variable Message Sign (Vms), Controller And Pole Mounted Cabinet","824.611" "1.000","Ls","Supports For Overhead Vms 195eb-Vms-36.9","840.311" "1.000","Ls","Supports For Overhead Vms 25eb-Vms-1.4","840.312" "1.000","Ls","Supports For Overhead Vms 25wb-Vms-7.3","840.313" "2100.000","Sf","Safety Signing For Traffic Management","852." "120.000","Ft","Temporary Pedestrian Barricade","852.11" "2.000","Ea","Temporary Pedestrian Curb Ramp","852.12" "3.000","Ea","Portable Breakaway Barricade Type Iii","853.1" "1440.000","Day","Truck Mounted Attenuator","853.403" "1440.000","Day","Arrow Board","856." "50.000","Day","Portable Changeable Message Sign","856.12" "14400.000","Day","Reflectorized Drum","859." "720.000","Day","Reflectorized Drums With Sequential Flashing Warning Lights","859.1" "17.000","Ea","Traffic Sign Removed And Reset","874.2" "1.000","Cy","4000 Psi, 1.5 Inch, 565 Cement Concrete For Post Foundation","901.3" |
||||
Details |
|
||||
Bidder's List | View project details and contacts | ||||
Prospective Bidders | View project details and contacts | ||||
Project Documents |
Engineered Spec Sheet Architectural Plans Other Documents |