Similar Projects
CalGulch Renovation Repair And Paint
Alteration
Bidding
Leadville, CO

Art Center Stair Installation
Alteration
Bidding
Glenwood Springs, CO 81601

Re-Plaster and Re-Tile The Bob Burger Recreation Center Lap Pool
Post-Bid
Lafayette, CO

Julesburg Rest Area EIFS Repair and Window Replacement
Post-Bid
Less than $160,000 est. value
Julesburg, CO 80737

Lone Tree Golf Clubhouse Exterior
Results
$150,000 to $200,000 est. value
Lone Tree, CO

Bear Park Phase III - Climate Battery and Dome Functionality
Results
Glenwood Springs, CO 81601

Exterior Restoration and Rehabilitation
Construction
Saguache, CO 81149

Rabbit Ears Pass Siding
Post-Bid
Less than $75,000 est. value
CO

Remediate Campus Fall Hazards, Phase 1 and Phase 2
Results
$800,000 est. value
Golden, CO 80401

Buffalo Run Golf Course Club House Stair Railing Replacement
Post-Bid
Commerce City, CO

Cu Den Bldg 1St Replace Main Doors
Results
Denver, CO

Woodman Hall Exterior Egress Stair Replacement Project
Post-Bid
Fountain, CO 80817

Exterior Stair Replacement - Timberline PK-8
Results
Longmont, CO 80504

Paired Panel Operable Wall Partitions
Post-Bid
Glenwood Springs, CO 81601

Nottingham Park Pavilion Water Proofing Repair Project
Results
Avon, CO 81620

Reported 06/02/2021 12:00 AM
Project Title

Nichols Hall Siding Project

Physical Address View project details and contacts
City, State (County) Rangely, CO 81648   (Rio Blanco County)
Category(s) Single Trades
Sub-Category(s) Finishes/Exterior
Contracting Method Competitive Bids.
Project Status Bidding
Bids Due View project details and contacts
Estimated Value $50,000
Plans Available from State Agency
Owner View project details and contacts
Architect View project details and contacts
Description

The Nichols North and South Resident Hall is located at Colorado Northwestern Community College (CNCC) in Rangely Colorado. The dormitory style facility was originally built in 1970 and consists of twin two story buildings, conjoined by a hallway and Campus Life Coordinator apartment. The exterior of the facility is currently sided with board and batten style siding, paired with roofing metal material around the windows (Approx. 5,300 sf). This project requires the removal of deteriorated siding, trim, and metal. Remove vapor barrier beneath exterior surface, and advise if any structural work is necessary. The project requires that the appropriate underlayment/backing be installed once structural repairs are conducted. The contractor will be required to install ½ underlayment in places that need replaced, replace all vapor barrier and window wrap and install 29-gauge vertical galvanized steel siding to reach a minimum of R-Value of 1.80 minimum

Details

Division 07 - Thermal and Moisture Protection, Siding.
Division 09 - Finishes.

Bidder's List View project details and contacts
Prospective Bidders View project details and contacts
Project Documents
 Engineered Spec Sheet
 Architectural Plans
 Other Documents