Similar Projects
Roof Repair and Replacement for Administration Buildings
Bidding
Pittsburgh, PA 15229

Replacement of Through-Wall Flashing
Bidding
Allison Park, PA 15101

Partial Roof Restoration of the Keystone Middle/Senior High School
Post-Bid
Pittsburgh, PA 15123

Roof Renovations
Post-Bid
Bethel Park, PA 15102

FM 6367 Construction Roof Replacement Allegheny County
Results
$100,000 to $199,999 est. value
PA

Courthouse Roof Replacement - Phase 2
Results
Less than $2,000 est. value
Pittsburgh, PA

Old Conservatory West Wing Roof Restoration and Replacement
Renovation
Construction
$450,000 est. value
Pittsburgh, PA 15123

Replacement of AHU-6 & AHU-7
Bidding
Allison Park, PA 15101

General Ancillary Services
Post-Bid
Pittsburgh, PA 15222

DPW Roof Replacement
Results
Less than $230,000 est. value
Pittsburgh, PA 15223

Roof Modifications for Screenings Garage and Power Generation Building
Bidding
Pittsburgh, PA 15233

Municipal Building Roof Coating
Post-Bid
PA

David E. Williams Middle School - Roof Restoration and Replacement
Results
Coraopolis, PA 15108

Allegheny Intermediate Unit Roof Replacement
Post-Bid
Clairton, PA

Medical Rescue Team South Authority Roof Replacement Project
Results
Pittsburgh, PA 15236

Last Updated 03/28/2019 03:24 PM
Project Title

Allegheny River, Lock/Dam No.2 Roofing Replacment

Physical Address View project details and contacts
City, State (County) Pittsburgh, PA 152061183   (Allegheny County)
Category(s) Single Trades
Sub-Category(s) Roofing
Contracting Method Competitive Bids.
Project Status Results
Bids Due View project details and contacts
Estimated Value $25,000 to $100,000
Plans Available from
Owner View project details and contacts
Architect View project details and contacts
Description Operations Building Powerhouse Roof - Remove the existing roofing materials, insulation, vent covers, and gravel stop from an approximately 2,200 square foot building and install a new, fully adhered, 60 mil EPDM roofing system, conforming to ASTM D4637/D4637M, with a new fascia/flashing system around the perimeter. Roofing system shall have new tapered insulation with R-Value of 20.5 and include the addition of any features to ensure positive drainage towards the roof drains. New flashing shall be installed on pipe vents protruding from roof surface. New vent cover and caps shall be installed on the generator exhaust pipe. The existing antenna system shall be relocated and then placed back on the new roof. The existing roof is approximately 2,200 square feet and consists of a concrete roof deck.
Details
Division 07 - Thermal and Moisture Protection, Dampproofing and Waterproofing, Thermal Protection.
Bidder's List View project details and contacts
Prospective Bidders View project details and contacts
Project Documents
 Engineered Spec Sheet
 Architectural Plans
 Other Documents