Last Updated | 03/21/2022 08:51 AM |
Project Title | Red Hat Amphitheater Power and Data Upgrades |
Physical Address | View project details and contacts |
City, State (County) | Raleigh, NC 27601 (Wake County) |
Category(s) | Single Trades |
Sub-Category(s) | Electric, Security/Communications |
Contracting Method | Competitive Bids. |
Project Status | Results |
Bids Due | View project details and contacts |
Estimated Value | $305,438 |
Plans Available from | |
Owner | View project details and contacts |
Architect | View project details and contacts |
Description | 1. Behind Section 4 seating - ADD Install 10 new circuits for Section 4. 2-220-volt (20 amp) volt receptacles. 8-110-volt (20 amp) volt receptacles all for wet location. Circuits are to be fed from two separate panels and circuits are to be divided evenly between. The panels are Panel D (100 amp) located at the back of section 4, the second panel is located inside the furthest east restroom facility perpendicular to S. McDowell Street. 2. Stage Left concession - ADD Add 2-220-volt (20Amp) amp volt receptacles. Add 8-110-volt (20 Amp) receptacles. Saw cut of Approximately 15’ of walkway. Circuits are to be fed from available spaces from the panel located in the Women’s room adjacent to the stage left area. Approximately 80’ away Data conduit- Provide one 4” PVC raceway for data from Stage left area through saw cut to handhole on the other side of the saw cut. Provide pull string in all data conduits. 3. 480-volt 400-amp three phase disconnect backstage left for future ice rink - ADD NEW Provide 400-amp three phase feeder with no neutral and an equipment ground from inside the convention center along driveway to backstage left location for disconnect. Install existing 400 amp disconnect on new back board. Provide new 400-amp breaker in main switchgear located near the elevators. This run would be in rigid conduit and is approximately 470’ long. 4. Data requirements behind restrooms - ADD Install a 4” PVC conduit and route back behind restroom area approximately 150’. Provide 5 handholes behind restrooms spaced evenly. Extend this raceway around to the new concession area for Section 4 to provide data access. 5. Pedestrian Gate 4 - ADD Add the following circuits in rigid conduit for the pavilion in front of Pedestrian Gate 4. 1-220-volt receptacle(20Amp) 4-110-volt receptacles (20Amp) Provide new breakers for circuits fed from panels already located in the pavilion. 6. Merchandise Tent - ADD 1-220-volt receptacle(20Amp) 4-110-volt receptacles (20Amp) |
||||||
Details |
|
||||||
Bidder's List | View project details and contacts | ||||||
Prospective Bidders | View project details and contacts | ||||||
Project Documents |
![]() Engineered Spec Sheet ![]() Architectural Plans ![]() Other Documents |