Last Updated 07/31/2020 06:05 AM
Project Title

Guardrail Rebuilding - /D08 GR FY2021

Physical Address View project details and contacts
City, State (County) (Butler, Clermont, Clinton, Greene, Hamilton, Montgomery, Preble, Warren Counties)
Category(s) Heavy and Highway
Sub-Category(s) Highway Signs/Guardrails/Barriers
Contracting Method Competitive Bids.
Project Status Results
Bids Due View project details and contacts
Estimated Value
Plans Available from
Owner View project details and contacts
Architect View project details and contacts
Description

Improving Various Sections In Butler, Clermont, Clinton, Greene, Hamilton, Preble, Montgomery, And Warren Counties Of Ohio, In Accordance With Plans And Specifications By Guardrail Repair And Replacement And Related Work. Section Roadway 0001 Line Item Code Quantity Unit Item Description Wt Alt 0001 202e38000 3,000.000 Ft Guardrail Removed (Wt: Nr) Nr 0002 202e38700 25.000 Each Guardrail Post Removed (Wt: Nr) Nr 0003 202e42001 9.000 Each Anchor Assembly Removed, Type a, As Per Plan (Wt: Nr) Nr 0004 202e98100 2.000 Each Removal Misc.:Impact Attenuator Removed With Site Preparation (Wt: Nr) Nr 0005 209e15000 8.000 Sta Reshaping Under Guardrail (Wt: 06) 06 0006 606e13000 900.000 Ft Guardrail, Type 5 (Wt: 36) 36 0007 606e13050 50.000 Ft Guardrail, Type 5a (Wt: 36) 36 0008 606e15050 900.000 Ft Guardrail, Type Mgs (Wt: 36) 36 0009 606e15100 1,200.000 Ft Guardrail, Type Mgs With Long Posts (Wt: 36) 36 0010 606e15150 50.000 Ft Guardrail, Type Mgs Half Post Spacing (Wt: 36) 36 0011 606e15200 50.000 Ft Guardrail, Type Mgs Half Post Spacing With Long Posts (Wt: 36) 36 0012 606e15250 50.000 Ft Guardrail, Type Mgs Quarter Post Spacing (Wt: 36) 36 0013 606e15300 50.000 Ft Guardrail, Type Mgs Quarter Post Spacing With Long Posts (Wt: 36) 36 0014 606e15350 50.000 Ft Guardrail, Type Mgs With Socketed Posts (Wt: 36) 36 0015 606e15500 25.000 Ft Guardrail, Barrier Design, Type 5 (Wt: 36) 36 0016 606e15550 25.000 Ft Guardrail, Barrier Design, Type Mgs (Wt: 36) 36 0017 606e16050 2,100.000 Ft Guardrail Rebuilt, Type Mgs (Wt: 36) 36 0018 606e16560 450.000 Ft Guardrail Rebuilt, Type Mgs With Long Posts (Wt: 36) 36 0019 606e16600 200.000 Ft Guardrail Rebuilt, Barrier Design, Type 5 (Wt: 36) 36 0020 606e16660 25.000 Ft Guardrail Rebuilt, Barrier Design, Type Mgs (Wt: 36) 36 0021 606e16700 25.000 Ft Guardrail Rebuilt, Type 5a (Wt: 36) 36 0022 606e16750 25.000 Ft Guardrail Rebuilt, Type Mgs Half Post Spacing (Wt: 36) 36 0023 606e16800 25.000 Ft Guardrail Rebuilt, Type Mgs Half Post Spacing With Long Posts (Wt: 36) 36 0024 606e16850 25.000 Ft Guardrail Rebuilt, Type Mgs Quarter Post Spacing (Wt: 36) 36 0025 606e16900 25.000 Ft Guardrail Rebuilt, Type Mgs Quarter Post Spacing With Long Posts (Wt: 36) 36 0026 606e17290 25.000 Ft Guardrail, Type 5, Long-Span (Wt: 36) 36 0027 606e17300 25.000 Ft Guardrail, Type 5, 25` Long-Span (Wt: 36) 36 0028 606e17360 25.000 Ft Guardrail, Type Mgs, Long-Span (Wt: 36) 36 0029 606e17900 25.000 Each Guardrail Post (Wt: 36) 36 0030 606e18501 10.000 Each Guardrail Post, 9 Feet, As Per Plan (Wt: 36) 36 0031 606e26000 2.000 Each Anchor Assembly, Type b (Wt: 36) 36 0032 606e26050 2.000 Each Anchor Assembly, Mgs Type b (Wt: 36) 36 0033 606e26100 6.000 Each Anchor Assembly, Type e (Wt: 36) 36 0034 606e26150 9.000 Each Anchor Assembly, Mgs Type e (Mash 2016 Or Nchrp 350) (Wt: 36) 36 0035 606e26500 5.000 Each Anchor Assembly, Type t (Wt: 36) 36 0036 606e26550 6.000 Each Anchor Assembly, Mgs Type t (Wt: 36) 36 0037 606e27841 9.000 Each Anchor Assembly Rebuilt, Type b, As Per Plan (Wt: 36) 36 0038 606e27847 2.000 Each Anchor Assembly Rebuilt, Mgs Type b, As Per Plan (Wt: 36) 36 0039 606e27851 121.000 Each Anchor Assembly Rebuilt, Type e, As Per Plan (Wt: 36) 36 0040 606e27861 36.000 Each Anchor Assembly Rebuilt, Mgs Type e, As Per Plan (Wt: 36) 36 0041 606e27901 13.000 Each Anchor Assembly Rebuilt, Type t, As Per Plan (Wt: 36) 36 0042 606e27911 5.000 Each Anchor Assembly Rebuilt, Mgs Type t, As Per Plan (Wt: 36) 36 0043 606e31101 1.000 Each Bridge Terminal Assembly Rebuilt, Type c, As Per Plan (Wt: 36) 36 0044 606e31601 1.000 Each Bridge Terminal Assembly Rebuilt, Type d, As Per Plan (Wt: 36) 36 0045 606e32101 1.000 Each Bridge Terminal Assembly Rebuilt, Type e, As Per Plan (Wt: 36) 36 0046 606e32171 1.000 Each Bridge Terminal Assembly Rebuilt, Type Tst, As Per Plan (Wt: 36) 36 0047 606e33051 1.000 Each Bridge Terminal Assembly Rebuilt, Type g, As Per Plan (Wt: 36) 36 0048 606e33601 1.000 Each Bridge Terminal Assembly Rebuilt, Type h, As Per Plan (Wt: 36) 36 0049 606e35000 3.000 Each Bridge Terminal Assembly, Type 1 (Wt: 36) 36 0050 606e35002 2.000 Each Mgs Bridge Terminal Assembly, Type 1 (Wt: 36) 36 0051 606e35006 2.000 Each Mgs Bridge Terminal Assembly, Type 1, Barrier Design (Wt: 36) 36 0052 606e35009 2.000 Each Mgs Bridge Terminal Assembly Rebuilt, Type 1, Barrier Design, As Per Plan (Wt: 36) 36 0053 606e35011 4.000 Each Bridge Terminal Assembly Rebuilt, Type 1, As Per Plan (Wt: 36) 36 0054 606e35013 2.000 Each Mgs Bridge Terminal Assembly Rebuilt, Type 1, As Per Plan (Wt: 36) 36 0055 606e35100 2.000 Each Bridge Terminal Assembly, Type 2 (Wt: 36) 36 0056 606e35102 2.000 Each Mgs Bridge Terminal Assembly, Type 2 (Wt: 36) 36 0057 606e35111 4.000 Each Bridge Terminal Assembly Rebuilt, Type 2, As Per Plan (Wt: 36) 36 0058 606e35113 2.000 Each Mgs Bridge Terminal Assembly Rebuilt, Type 2, As Per Plan (Wt: 36) 36 0059 606e35131 1.000 Each Bridge Terminal Assembly Rebuilt, Type 3, As Per Plan (Wt: 36) 36 0060 606e35151 1.000 Each Bridge Terminal Assembly Rebuilt, Type 4, As Per Plan (Wt: 36) 36 0061 606e60002 2.000 Each Impact Attenuator, Type 1 (Unidirectional) (Wt: 36) 36 0062 606e60012 10.000 Each Impact Attenuator, Type 1 (Bidirectional) (Wt: 36) 36 0063 606e60022 1.000 Each Impact Attenuator, Type 2 (Unidirectional)70 Mph, 36" (Wt: 36) 36 0064 606e60028 1.000 Each Impact Attenuator, Type 2 (Bidirectional)70 Mph, 36" (Wt: 36) 36 0065 606e60050 1.000 Each Impact Attenuator, Type 3 (Bidirectional)70 Mph, 90" (Wt: 36) 36 0066 606e60060 1.000 Each Impact Attenuator Rebuilt, Type 1 (Unidirectional), As Per Plan (Wt: 36) 36 0067 606e60070 8.000 Each Impact Attenuator Rebuilt, Type 1 (Bidirectional), As Per Plan (Wt: 36) 36 0068 606e61000 6.000 Each Impact Attenuator, Misc.:Belt Nose Assembly (Quardguard) (Wt: 36) 36 0069 606e61000 40.000 Each Impact Attenuator, Misc.:Cartridge, Type 1 (Quadguard) (Wt: 36) 36 0070 606e61000 35.000 Each Impact Attenuator, Misc.:Cartridge, Type 2 (Quardguard) (Wt: 36) 36 0071 606e61000 4.000 Each Impact Attenuator, Misc.:Cylinder Qe1 (Quadguard Elite) (Wt: 36) 36 0072 606e61000 4.000 Each Impact Attenuator, Misc.:Cylinder Qe2 (Quadguard Elite) (Wt: 36) 36 0073 606e61000 9.000 Each Impact Attenuator, Misc.:Diaphram Assembly (24"-36") (Quadguard) (Wt: 36) 36 0074 606e61000 4.000 Each Impact Attenuator, Misc.:Diaphram Assembly (48") (Quadguard) (Wt: 36) 36 0075 606e61000 4.000 Each Impact Attenuator, Misc.:Diaphram Assembly (69"-90") (Quadguard) (Wt: 36) 36 0076 606e61000 25.000 Each Impact Attenuator, Misc.:Fender Panel Assembly (Quadguard) (Wt: 36) 36 0077 606e61000 3.000 Each Impact Attenuator, Misc.:Plastic Nose Piece (Tracc 2005) (Wt: 36) 36 0078 606e61000 3.000 Each Impact Attenuator, Misc.:Reflective Sheeting (Tracc 2005) (Wt: 36) 36 0079 606e61000 18.000 Each Impact Attenuator, Misc.:Reset Attenuator (Wt: 36) 36 0080 606e61000 4.000 Each Impact Attenuator, Misc.:Rip Plate, Stage 2 (Tracc 2005) (Wt: 36) 36 0081 606e61000 2.000 Each Impact Attenuator, Misc.:Shredder Assembly (Tracc 2005) (Wt: 36) 36 0082 606e61000 11.000 Each Impact Attenuator, Misc.:Two Way Fender Panel (Tracc 2005) (Wt: 36) 36 0083 606e98000 800.000 Ft Guardrail, Misc.:Type 5 Rebuilt Using Steel Post (Wt: 36) 36 0084 606e98000 10,400.000 Ft Guardrail, Misc.:Type 5 Rebuilt Using Wood Post (Wt: 36) 36 0085 606e98100 40.000 Each Guardrail, Misc.:Urgent Repair (Wt: 36) 36 0086 690e98000 1.000 Each Special - Misc.: Concrete Barrier End Section (Wt: 36) 36 0087 690e98700 5.000 Cy Special - Misc.: Class Qc1, Concrete Barrier Repair (Wt: Nr) Nr 0088 690e98700 5.000 Cy Special - Misc.: Class Qc2, Superstructure Barrier Repair (Wt: Nr) Nr Section Pavement 0002 Line Item Code Quantity Unit Item Description Wt Alt 0089 609e24510 40.000 Ft Curb, Type 4-c (Wt: 38) 38 Section Lighting 0003 Line Item Code Quantity Unit Item Description Wt Alt 0090 625e14400 1.000 Each Light Pole Foundation Repair (Wt: 43) 43 Section Traffic Control 0004 Line Item Code Quantity Unit Item Description Wt Alt 0091 626e00110 125.000 Each Barrier Reflector, Type 2, Bidirectional (Wt: Nr) Nr 0092 690e98100 200.000 Ft Special - Linear Delineation System (Wt: Nr) Nr Section Maintenance Of Traffic 0005 Line Item Code Quantity Unit Item Description Wt Alt 0093 614e11110 75.000 Hour Law Enforcement Officer With Patrol Car For Assistance (Wt: 39) 39 0094 614e13600 155.000 Each Maintenance Of Traffic, One Lane Closure On a Two Lane Highway (Wt: 39) 39 0095 614e13700 15.000 Each Maintenance Of Traffic, One Lane Closure On a Four Lane Undivided Highway (Wt: 39) 39 0096 614e13800 45.000 Each Maintenance Of Traffic, One Lane Closure On a 4 Lane Or Greater Divided Highway (Wt: 39) 39 0097 614e13800 15.000 Each Maintenance Of Traffic, One Lane Closure On a 4 Lane Or Greater Divided Highway(City Of Cincinnati) (Wt: 39) 39 0098 614e13900 335.000 Each Maintenance Of Traffic For Shoulder Closure (Wt: 39) 39 0099 614e13900 80.000 Each Maintenance Of Traffic For Shoulder Closure(City Of Cincinnati) (Wt: 39) 39 Section Miscellaneous Structure 0006 Line Item Code Quantity Unit Item Description Wt Alt 0100 517e70001 50.000 Ft Railing (Twin Steel Tube), As Per Plan (Wt: 36) 36 0101 517e72205 50.000 Ft Railing (Deep Beam Rail With Steel Tubular Backup And Type 1 Steel Posts), As Per Plan (Wt: 36) 36 0102 517e72307 50.000 Ft Railing (Deep Beam Rail With Steel Tubular Backup And Type 2 Steel Posts), As Per Plan (Wt: 36) 36 Section Incidentals 0007 Line Item Code Quantity Unit Item Description Wt Alt 0103 103e05000 1.000 Ls Premium For Contract Performance Bond And For Payment Bond (Wt: Nr) Nr 0104 624e15000 455.000 Each Mobilization (Wt: Nr) Nr

Details

Division 01 - General Requirements, Temporary Barriers and Enclosures.
Division 34 - Transportation, Guideways/Railways.

Bidder's List View project details and contacts
Prospective Bidders View project details and contacts
Project Documents
 Engineered Spec Sheet
 Architectural Plans
 Other Documents