Last Updated 06/02/2021 02:09 PM
Project Title

Preventative Maintenance Back Up Generator

Physical Address View project details and contacts
City, State (County) Secaucus, NJ   (Hudson County)
Category(s) Single Trades
Sub-Category(s) Electric
Contracting Method Competitive Bids.
Project Status Results
Bids Due View project details and contacts
Estimated Value
Plans Available from
Owner View project details and contacts
Architect View project details and contacts
Description

The services that are requested will be for all of the Housing Authorities generators (Onan150.0DVE-15R/26985A, Kohler-100R084, and Kohler-8()ROZ581) and will include the following: 1) Change Lubricating oil and oil ilters a minimum ofonce during each 12 months period; 2) Perform laboratory analysis of used oil and submit report to the Housing Authority for review; 3) Change fuel oil ilters a minimum of once during each 12 month period; 4) Replace air filter once during each 12 month period; 5) Adjust valves; 6) Drain and lush coolant system & refill with 50% antireeze solution once every 12 months; 7) Perform laboratory analysis of coolant sample and submit report to the Housing Authority for review; 8) Inspect, adjust and replace fan belts as necessary; 9) Check flex connections and mountings; 10) Check operation ofjacket water heater; 11) Check and maintain battery level and charging equipment; 12) Lubricate necessary fittings; 13) Inspect governor linkage, oil level and control; 14) Repair minor coolant, lube and iiel leaks; 15) Inspection day tank and pump control; 16) Inspect spark plugs, magneto and coils (replace ifnecessary); 17) Drain condensate rom day tank ifnecessary; 18) Check operation ofremote fans, pumps & louvers; 19) Inspect generator slip rings and clean ifnecessary; 20) Operate electronic set and check or reset for correct voltage & requency; 21) Check auto start-stop mode; 22) Simulate each safety shutdown; 23) Test fault lamps & replace bad bulbs; 24) Load test machine and check operation of transfer switch (must get permission to do this test) 25) Maintain a written log, on site, indicating all service performed & dates of service calls. 26) Respond to all emergency calls within 2 hours ofreceiving the trouble call.

Details

Division 26 - Electrical, Packaged Generator Assemblies.

Bidder's List View project details and contacts
Prospective Bidders View project details and contacts
Project Documents
 Engineered Spec Sheet
 Architectural Plans
 Other Documents