Similar Projects
Hawthorn MS North Boiler Replacement
Bidding
Vernon Hills, IL 60061

Fairmount ES Mechanical Upgrades
Bidding
Downers Grove, IL 60516

East Moline Correctional Center Boiler Acid Wash
Post-Bid
East Moline, IL 61244

Boiler and Hot Water Heater Maintenance
Term Contract
Post-Bid
Downers Grove, IL

Niles West Domestic Water Heater Replacement
Renovation
Results
Skokie, IL 60077

Building B Boiler Replacement Service
Results
Crystal Lake, IL 60012

2021 Fire Alarm System, Boiler Upgrades and Freezer Replacement
Bidding
Loves Park, Machesney Park, IL 61115

Abandoned Rooftop Equipment Removal
Post-Bid
Palatine, IL 60067

Water Heater Replacement
Results
Deerfield, IL 60015

FDC Mechanical Systems/Envelope Upgrades
Bidding
University Park, IL

Repair Boilers
Post-Bid
$100,000 to $250,000 est. value
IL

Water Treatment Plant Boiler Replacement
Results
Hudson, IL 61748

Fenton HS Ionization Existing Mechanical Equipment
Bidding
Bensenville, IL 60106

DHS/Elgin MHC Refrigeration
Term Contract
Post-Bid
Elgin, IL 60123

Boiler Replacement at Dawes Elementary School Annex Building and Washington Elementary School Annex Building
Results
Evanston, IL 60202

Reported 12/02/2020 12:00 AM
Project Title

DHS SP ISD HEPA UV Filtration System

Physical Address View project details and contacts
City, State (County) Jacksonville, IL   (Morgan County)
Category(s) Single Trades
Sub-Category(s) Mechanical
Contracting Method Competitive Bids.
Project Status Bidding
Bids Due View project details and contacts
Estimated Value
Plans Available from State Agency
Owner View project details and contacts
Architect View project details and contacts
Description

To procure eight HEPA filtration systems and filters for ISD. 120V with UV (ultraviolet lamp) model; portable, self-contained high efficiency particulate air (HEPA) filtration system; contains HEPA filter and pre-filter; creates a negative pressure isolation room that will meet OSHA and CDC TB guidelines; can be sued as a positive pressure clean air recirculating system or as a partial or complete exhausting system to create a negative pressure isolation room for possible use with patients known or suspected of having TB, SARS, or other infectious diseases; 3 speed motor/blower can deliver 560 CFM (951 m3/hr) to 800 CFM (1359 m3/hr); as negative pressure unit- the air through HEPA filter is cleansed of 99.9% of particles as small as 0.3 micron and exhausted directly to the exterior through a window; quite operation - 50mBA or lower; provides up to 24 room air changes per hour in 18x12x8ft room or up to 12 room air changes per hour in 3,900 cubic feet room.

Details

Division 46 - Water and Wastewater Equipment, Filtration Equipment.

Bidder's List View project details and contacts
Prospective Bidders View project details and contacts
Project Documents
 Engineered Spec Sheet
 Architectural Plans
 Other Documents