Similar Projects
Last Updated | 05/24/2023 04:03 AM |
Project Title | Western High School - SMART Program Renovations |
Physical Address | View project details and contacts |
City, State (County) | Davie, FL 33325 (Broward County) |
Category(s) | Education |
Sub-Category(s) | Middle/Senior High School |
Contracting Method | Competitive Bids |
Project Status | Bidding, Construction start expected July 2023 |
Bids Due | View project details and contacts |
Estimated Value | $3,000,000 [brand] Estimate |
Plans Available from | Agency's Affiliate |
Owner | View project details and contacts |
Architect | View project details and contacts |
Description | The scope of work for this project includes but is not limited to the following tasks: -- Work of this Contract comprises general construction of Safety/Security Upgrades, Building Envelope Improvements (Roof, Window, Exterior Walls, etc.), Electrical Improvements, and HVAC Improvements. Bid Bond 5% TOTAL LUMP-SUM AMOUNT Plan (blueprint) Electronic plan documents eBidding No Architectural Reroofing of building 3. Complete replacement of windows in building 1, building 4. Installation of new flooring in building 1 media center. Providing new furniture and cabinetry for media center in building 1. New cabinetry to be provided for building 2 stem lab. Complete installation of overhead door in west facade of building 2 for stem lab. Painting of soffit in building 2 and 4. Painting of building exterior of building 4 and 7. Mechanical Perform test & balance in building 1, 2, 4, 6, 11, 12, 13, 14, 15, 16, and 17 Replace (3) air handling units in building 2 Replace ductwork in building 2 and 4 Install new duct heater in building 4. Replace DDC control system in building 2, 3, and 4 Install new hood in building 2 Replace water heater in building 3 Replace A/C window unit with split DX system for building 3. Install new dx split system in building 4. Install necessary components to make refrigerant leak detection system in room - code compliant. Reference sheet m-29 for RLDS sequence of operation, sheet m-28 for RLDS notes, and sheet m-24 for RLDS riser diagram. Install necessary components/controls to make RLDS operate according to RLDS sequence of operation in building 3. Remove existing air handling unit from hydronic system. Cap CHS & CHR lines in building 4. Install new louvered wall vent in building 17. Replace existing a/c package unit (typ) in all portables (except 1499p, 1504p, & 1515p) Electrical Replacement of building mounted lights in building 1, building 2 and portables. Replacement of exit signage in building 1, building 2, building 3. Replacement of canopy lighting in building 4 and building 16. Replacement of pole lighting in site. Replacement of battery pack lighting in building 4 Replacement of electrical panel in building 4 9980 |
||||||||||||||||||||||||||||||||||||||
Details |
|
||||||||||||||||||||||||||||||||||||||
Bidder's List | View project details and contacts | ||||||||||||||||||||||||||||||||||||||
Prospective Bidders | View project details and contacts | ||||||||||||||||||||||||||||||||||||||
Project Documents |
Engineered Spec Sheet Architectural Plans Other Documents |