Similar Projects
Last Updated | 04/27/2023 05:17 PM |
Project Title | Southwest Technical College a&t Building Sidewalk Paving and Waterway |
Physical Address | View project details and contacts |
City, State (County) | Cedar City, UT 84720 (Iron County) |
Category(s) | Heavy and Highway |
Sub-Category(s) | Paving/Reconstruction, Sidewalks/Parking Lot, Site Development |
Contracting Method | Bids by Invitation, Competitive Bids |
Project Status | Bidding, Construction start expected May 2023 |
Bids Due | View project details and contacts |
Estimated Value | $196,000 [brand] Estimate |
Plans Available from | State Agency |
Owner | View project details and contacts |
Architect | View project details and contacts |
Description | See Project Description on page 4 for contact information and list of pre-qualified contractors. QUESTIONS DEADLINE Friday, April 21, 2023 3:00 PM SCOPE This section of the specifications cover specific requirements, instructions, and conditions applicable to this project only, which are not covered by the General Conditions of the Construction Contract prepared by the Engineers Joint Contract Documents Committee. Should there be conflicting statements between this section and other sections of these specifications, this section shall govern. Should there be conflicting statements between the Standard General Conditions of the Construction Contract, these specifications or the Utah Division of Facilities Construction and Management (DFCM) Contractors Agreement. The order of precedence is as follows: 1. DFCM Contractors Agreement. 2. These Specifications 3. Standard General Conditions of the Construction Contract. The following documents are required before a certificate of occupancy is issued: o A code inspection report recommending that a certificate of occupancy be issued. o Final report from the special inspection agency. o Certificate of fire clearance from the State Fire Marshall. o Final approval from the State Elevator inspector, if applicable. N/A o Final approval from the State boiler inspector, if applicable. N/A o Report of the disinfection of the potable water system. IPC 610 N/A o A Certificate of Compliance from the approved fabricator, if applicable. IBC 1074.2.2 N/A o A stamped and signed final report from the structural engineer when structural observation is required by IBC 1710. N/A o An NFRC Certificate for fenestration without the NFRC label. N/A o Final report from the special inspector and the mechanical engineer when smoke control is required. The reports must comply with IBC 909.18.8.3. N/A |
||||
Details |
|
||||
Bidder's List | View project details and contacts | ||||
Prospective Bidders | View project details and contacts | ||||
Project Documents |
Engineered Spec Sheet Architectural Plans Other Documents |