Similar Projects
BSL 3 Laboratory HVAC and Controls Renovation
Renovation, Alteration
Bidding
Kissimmee, FL 34741

FSU CAPS 70-Ton Chiller
Alteration
Bidding
Tallahassee, FL 32310

Doyle Conner Administration Building HVAC Improvements
Post-Bid
Less than $850,000 est. value
Tallahassee, FL 32399

SOB and HOB, HVAC Cleaning
Post-Bid
Tallahassee, FL

On-Call HVAC Services
Results
Tallahassee, FL 32312

FSU Keen Building HVAC Basement Replacement
Results
Tallahassee, FL 32306

Bryant Building Chiller and Boiler Replacement
Post-Bid
Tallahassee, FL 32399

Heating, Ventilation and Air Conditioning (HVAC) Replacement - North Region
Results

Doyle Conner Lab Administration Building Air Distribution Improvements
Post-Bid
Tallahassee, FL 32399

HVAC Replacement Project for Smith Williams Center
Results
Tallahassee, FL 32310

Florida A and M University Lab 152 Remodel - Fume Hood Installation
Post-Bid
Tallahassee, FL 32310

Gilchrist Elementary School Building 9 HVAC Replacement
Results
Tallahassee, FL 32312

HVAC and Mechanical Products
Term Contract
Post-Bid

Rooftop Unit (RTU) Replacement
Results

Gemini ES CEP Upgrades
Post-Bid
Melbourne Beach, FL 32951

Last Updated 08/09/2021 09:56 AM
Project Title

FSU Sandels Building HVAC Duct Cleaning

Physical Address View project details and contacts
City, State (County) Tallahassee, FL 32304   (Leon County)
Category(s) Single Trades
Sub-Category(s) HVAC
Contracting Method Competitive Bids.
Project Status Results
Bids Due View project details and contacts
Estimated Value
Plans Available from
Owner View project details and contacts
Architect View project details and contacts
Description

To decontaminate and sanitize, all interior non-porous (metal) surfaces and decontaminate and coat all interior porous surfaces (lined) (see ductwork insulation coating section 1.5) of the Heating, Ventilation, and Air Conditioning System (HVAC) associated with and including Air Handling Units 1, 2, 3, 4, 5, and 6 of Sandel’s Building as shown on the As Built Mechanical drawings for the building. Where internal insulation in ductwork is beyond salvage, the contractor shall replace the insulation and coat it using materials specified. The HVAC system is any interior surface of a buildings air distribution system for conditioned spaces and/or occupied zones. This includes the entire air moving system from the points that the air enters the system to the points where the air is discharged from the system. The return air grilles, air ducts (except ceiling plenums), supply air ducts, turning vanes, and reheat coils are considered part of the HVAC system. Exhaust systems are not considered part of the HVAC system. The drawings are intended to indicate diagrammatically the intent, character, and approximate location of work. Where work is indicated with minor details omitted, furnish, and install such work complete as required to perform its intended function

Details

Division 23 - Heating, Ventilating, and Air Conditioning (HVAC), Instrumentation and Control for HVAC, HVAC Air Distribution, Central HVAC Equipment.

Bidder's List View project details and contacts
Prospective Bidders View project details and contacts
Project Documents
 Engineered Spec Sheet
 Architectural Plans
 Other Documents