Similar Projects
Jenkins Terrace / Worley Terrace - Lighting Upgrades
Bidding
$300,000 est. value
Columbus, OH

LED Lighting Upgrades Project 2
Post-Bid
Less than $360,000 est. value
Middletown, OH 45044

Electrician Services
Term Contract
Post-Bid
Springfield, OH 45503

Purchase of Distribution Transformers
Results
Cleveland, OH

Safety and Security Upgrades for the Electrical Service
Results
Andover, OH 44003

Central Recreation Center Electrical Improvements
Post-Bid
Cleveland, OH 44114

2019 DCS Electrical Improvements
Results
Dublin, OH

CSU Theatre and Dance LED Lighting Package
Post-Bid
Cleveland, OH 44115

WWTP Standby Generator
Results
Less than $145,000 est. value
New Concord, OH 43762

15 KV Cable Replacement
Post-Bid
Cincinnati, OH 45221

Wastewater Treatment Generator Replacement
Results
Gratis, OH

750 Kva Network Transformer
Post-Bid
Hamilton, OH 45011

Electrical Equipment Installation of 5MVA Transformers and 3-Way Switches, Conduit, Wire, and Related Equipment for CF1
Results
Cuyahoga Falls, OH 44221

Building Asbestos Containing Light Fixture Removal
Post-Bid
Columbus, OH

S and DJP - Schneider VFDS
Results
Columbus, OH

Reported 02/29/2020 12:00 AM
Project Title

Battery Load Test System

Physical Address View project details and contacts
City, State (County) Columbia, OH   (Tuscarawas County)
Category(s) Single Trades
Sub-Category(s) Electric
Contracting Method Competitive Bids.
Project Status Request for Quotations
Bids Due View project details and contacts
Estimated Value
Plans Available from Federal Agency
Owner View project details and contacts
Architect View project details and contacts
Description

1. Minimum warranty: Parts, labor, and travel: Two (2) Years Standard Warranty from date of installation at the DLA Product Test Center, Electronics Lab, Columbus, OH. 2. Quoted battery load test system shall have been on the market in the USA for a minimum of 3 years. 3. The contractor shall have a field service department capable to respond within 48 hours for system repair. 4. The contractor shall have inventory of spare parts within the USA that can be shipped within 48 hours in the event of system repair. 5. Basic operator training (estimated 2 days) shall be at the DLA Land and Maritime Product Test Center location, Columbus, OH for not more than 5 associates. 6. All training materials shall be supplied by the contractor. 7. The contractor shall be responsible for installation and start up, which consists of 1) verifying proper wiring of the battery test system to the power disconnect box, 2) turn system on, run diagnostics, and verify system operation, 3) demonstrate to PTC personnel the system meets specifications. 8. Cost for shipping must be included. 9. Delivery: 16 weeks from Contract Award Date.

Details

Division 26 - Electrical.

Bidder's List View project details and contacts
Prospective Bidders View project details and contacts
Project Documents
 Engineered Spec Sheet
 Architectural Plans
 Other Documents