Similar Projects
Boiler Replacement, Nipmuc Regional High School - General Bids
Alteration
Bidding
$1,106,437 est. value
Upton, MA 01568

275 Bi-Polar Air Purifier Ionization Units and One Monitoring Device
Post-Bid
Auburn, MA

C2104 Dupont Feedwater Pump Replacement
Post-Bid
Less than $24,000 est. value
Fitchburg, MA 01420

Boiler Replacement Northbridge Middle School - General Bids
Results
Less than $2,395,065 est. value
Northbridge, Whitinsville, MA 01588

New Mechanical Installation for Building B Addition
Results
$200,000 est. value
Worcester, MA

Mckay Steam Valves Replacement
Post-Bid
$19,000 est. value
Fitchburg, MA 01420

Oil Burner Service and/or Boiler Cleaning Service
Results
$55,000 est. value
Jefferson, MA

Emergency and Non-Emergency Repair Service and On-Call Mechanical and Facilities Repair
Alteration
Post-Bid
$200,000 est. value
Milford, MA

Electric Hot Water Heater Replacement
Results
$38,000 est. value
Athol, MA 01331

Heating Boiler Replacement Ghosh Science and Technology Center
Results
$649,820 est. value
Worcester, MA 01602

Delivery and Installation of Electrical, Mechanical
Alteration
Results
$40,000 to $60,000 est. value
Whitinsville, MA

Plumbing, Heating, and Mechanical Services
Term Contract, Alteration
Results
$130,000 est. value
Westborough, MA

Boiler Condensate System Repairs, Administration Building
Alteration
Results
$49,700 est. value
Worcester, MA 01606

Temporary Boiler at Crocker Elementary School
Alteration
Results
$95,000 est. value
Fitchburg, MA 01420

Boiler Replacement
Alteration
Results
$105,000 est. value
Holden, MA

Last Updated 12/09/2021 04:38 PM
Project Title

Boiler Replacement, Nipmuc Regional High School - Filed Sub Bids

Physical Address View project details and contacts
City, State (County) Upton, MA 01568   (Worcester County)
Category(s) Single Trades
Sub-Category(s) Mechanical
Contracting Method Competitive Bids.
Project Status Results
Bids Due View project details and contacts
Estimated Value $1,106,437
Plans Available from
Owner View project details and contacts
Architect View project details and contacts
Description

DCAMM Certificate Required. Removal and replacement of existing gas fired hot water boilers, circulation pumps, associated equipment, piping, and wiring at the existing boiler room. New boilers will be vented through the existing exterior wall. Add Alternates include cast iron condensing boilers in lieu of specified boilers, and removal of the existing boiler vent stack

Details

Division 22 - Plumbing.
Division 23 - Heating, Ventilating, and Air Conditioning (HVAC), Heating Boilers.
Division 26 - Electrical.

Bidder's List View project details and contacts
Prospective Bidders View project details and contacts
Project Documents
 Engineered Spec Sheet
 Architectural Plans
 Other Documents