Similar Projects
Amerikooler Walk-in Cooler or Approved Equal Brand
Renovation
Design
$200,000 CJ est. value
Monroe, GA 30655

RFP D/B - Design/Build Services for HVAC Automation Control Upgrades
Renovation
Bidding
$3,685,500 CJ est. value
Stone Mountain, GA 30083

2023 HVAC Replacement
Renovation
Sub-Bidding
$200,000 CJ est. value
Atlanta, GA 30324

North Police Precinct HVAC Replacement
Renovation
Sub-Bidding
$600,000 CJ est. value
Buford, GA 30519

HVAC Maintenance
Alteration
Post-Bid
Metter, GA 30439

HVAC Replacement for the Macon Housing Authority Central Office
Alteration
Post-Bid
Macon, GA 31201

Design Build Services for The Replacement/Refurbishment of AHUs and Associated Fans
Results
GA

GCHS Central Plant HVAC Replacement
Results
$965,000 est. value
Greensboro, GA 30642

Awtrey Middle School HVAC Upgrade, Phase 2
Renovation
Sub-Bidding
$650,000 CJ est. value
Kennesaw, GA 30144

HVAC Maintenance Contract 2021-2023
Term Contract
Post-Bid
Waynesboro, GA 30830

Courthouse HVAC
Alteration
Results
Ringgold, GA 30736

Berrien Middle School Corridor HVAC
Renovation
Sub-Bidding
$300,000 CJ est. value
Nashville, GA 31639

Georgia Weatherization Assistance Program
Alteration
Post-Bid
Jasper, GA

HVAC Replacement
Infrastructure
Results
Cumming, GA 30040

Computer Technology And Mathematics Classroom Building (CTM) And Gayles-felton Academic Classroom & Lab Building (ACL) Boiler Replacements
Renovation
Sub-Bidding
$300,000 CJ est. value
Fort Valley, GA 31030

Last Updated 05/05/2023 09:31 AM
Project Title

J Building Chiller Replacement

Physical Address View project details and contacts
City, State (County) Albany, GA 31707   (Dougherty County)
Category(s) Single Trades
Sub-Category(s) HVAC
Contracting Method Competitive Bids
Project Status All Bids Received, Selection Underway, Construction start expected April 2023
Bids Due View project details and contacts
Estimated Value $300,000 [brand] Estimate
Plans Available from Agency's Affiliate
Owner View project details and contacts
Architect View project details and contacts
Description

The project is located at the J Building - Allied Health, Community Service and Theatre Building on the West Campus of Albany State University. The purpose of the project is to to replace the chiller. - Check in with Customer to gain access and go over the installation plan - Disconnect existing power supply at main panel - Isolate existing chiller, drain CW lines and machine - Recover refrigerant, remove existing chiller, and dispose of per code - Receive, deliver, and set new chiller - Reconnect CW and cond water piping to existing lines at nearest ISO valve - Reinsulate CW lines from the chiller to that connection point - Reconnect all ancillary devices and connections that were removed for the swap Including vent piping, gauges, thermometers, flow switches, etc. o Refill all the lines with water o Reconnect main power connections to new chiller o Reconnect controls as follows: 1. Refrigerant monitor, relays, cable, wire, conduit, and miscellaneous accessories. 2. Perform all labor to program, checkout, and assist test and balance contractor, to make the above stated controls equipment work properly according to the written sequence of operations. 3. Tie all newly installed DDC Controls into the existing campus wide building automation system 4. Provide Submittals, As-Built Engineered Drawings, and 10 Year Warranty 5. Provide owner training to instruct the owner on how to use system. - Provide FACTORY startup of new chiller - Run new chiller and check for proper operation - Perform Test and balance of new chiller - Clean up work area

Details

Division 23 - Heating, Ventilating, and Air Conditioning (HVAC), Instrumentation and Control for HVAC, HVAC Air Distribution, Central HVAC Equipment.

Bidder's List View project details and contacts
Prospective Bidders View project details and contacts
Project Documents
 Engineered Spec Sheet
 Architectural Plans
 Other Documents