Similar Projects
Replace Kitchen Air Handling Unit Boulder City High School
Alteration
Bidding
$271,000 est. value
Boulder City, NV 89005

Fume Hood
Post-Bid
Las Vegas, NV

Replace Ductwork In Dehumidifiers
Post-Bid
Las Vegas, Nelson, NV

J045--Chiller Comprehensive Service and Maintenance
Results

SWRF Untreated Air Pipe Replacement
Results
$1,225,000 est. value
Henderson, NV

99 Ces Replacement Boiler Building 777
Term Contract
Post-Bid
Nellis AFB, Nellis Air Force Base, NV 89191

West Charleston Building C - 2nd Floor HVAC Replacement Phase A
Results
$319,000 est. value
Las Vegas, North Las Vegas, NV 89146

Central Plant Renovation, High Desert State Prison
Alteration
Post-Bid
$7,300,000 est. value
NV

West Flamingo Senior Center Pool Locker Room HVAC Upgrade
Results
$126,350 to $133,000 est. value
Las Vegas, NV

90 Ton High Ambient Air-Cooled Chiller
Alteration
Post-Bid
Las Vegas, NV 89106

Satellite Energy Plant (SEP) Cooling Tower Repair
Results
$350,000 est. value
Las Vegas, NV 89154

Replace HVAC Components, Roof, and Security Walter Johnson Junior High School Academy of International Studies
Alteration
Post-Bid
$7,614,477 est. value
Las Vegas, NV 89145

45--Supply and Replace HVAC Units
Results
Bullhead City, AZ - Boulder City, Echo Bay, NV 89005

Air Duct Cleaning Set-Up
Term Contract
Post-Bid

UNLV CBC-C 1st and 2nd Floor Repipe
Results
$820,000 est. value
Las Vegas, NV 89154

Last Updated 05/20/2022 12:15 AM
Project Title

CBC (Classroom Building Complex) Cooling Towers Repairs

Physical Address View project details and contacts
City, State (County) Las Vegas, NV 89154   (Clark County)
Category(s) Single Trades
Sub-Category(s) HVAC
Contracting Method Competitive Bids.
Project Status Results
Bids Due View project details and contacts
Estimated Value $108,000 [brand] Estimate
Plans Available from
Owner View project details and contacts
Architect View project details and contacts
Description

Three existing cooling towers at the CBC (Classroom Building Complex) need immediate repairs. The scope of work to restore the towers to reliable, efficient, and safe operation includes the following measures: 1. Obtain all necessary state and local permits to perform this type of work. 2. Follow all UNLV standards and guidelines for contractors performing work on site. 3. Provide a detailed schedule for executing all aspects of the scope of work required. 4. Secure three towers with lock out-tag out and drain each tower. Stage operations to allow operation of at least one cooling tower when necessary. 5. Replace drift eliminators with new OEM drift eliminators. 6. Replace fill material with new OEM fill. 7. Install 316 stainless steel drip angle extensions (12 total). 8. Adjust fan belts for proper tension. 9. Inspect and grease sliding motor bases. 10. Clean cooling tower external surfaces using non-corrosive scale remover to the maximum capability of the scale remover without damaging the material. 11. Fill three cooling towers and restore electricity for operation. 12. Remove all waste and demolished materials from the site and dispose of them properly and recycle when possible. 13. Commissioning of the cooling towers to demonstrate proper operation of the cooling towers after repairs are completed. 14. Provide four (4) hours of classroom and in-person training by factory-certified trainers on the proper operations of the refurbished cooling towers prior to final acceptance.

Details

Division 23 - Heating, Ventilating, and Air Conditioning (HVAC), Instrumentation and Control for HVAC, HVAC Air Distribution, Central HVAC Equipment.

Bidder's List View project details and contacts
Prospective Bidders View project details and contacts